Operating Noises 

To reach the desired temperature settings, Our Steak Ager, like all products operating with compressors and fans, 
may produce the following types of noises. These noises are normal and may occur as follows: 
 
1.

 

Gurgling sound - caused by the refrigerant flowing through the appliance’s coils. 

2.

 

Cracking/popping sounds - resulting from the contraction and expansion of the refrigerant gas to produce 
cold. 

3.

 

Fan operating sound - to circulate the air within the Steak Ager 

4.

 

“Pa Pa” sound – Solenoid valve start sound 

5.

 

"Sizzle" sound: It is caused by the refrigerant flowing in the pipeline after the solenoid valve of the system is 
opened 

 
An individual’s perception of noise is directly linked to the environment in which the Steak Ager is located, as 
well the specific type of models. Our Steak Ager  are in line with international standards for such appliance. We 
will always do its utmost to satisfy its customers but will not retake possession of the goods due to complaints 
based on normal operating noise occurrences. 
 

Start Tips  

1.

 

Clean the inside of the Steak Ager with disinfectant, which shouldn’t be aggressive.  

2.

 

If ordered: unpack the salt blocks and remove the foil. Put the salt blocks in the stainless steel tray and place 
the tray at the bottom of the cabinet. Please check every 2-3 days if there is any remaining water on the salt 
blocks, if so, please remove the water. 

3.

 

The temperature and humidity are already set on 1°C and 85% humidity which are the perfect setting for 
dry aging beef &pork. 

4.

 

The meat for the dry aging must be fresh, perfect would be max. 5 days after slaughtering. Even vacuum 
matured meat can be used, but for a maximum of 14 days (please remove foil) 

5.

 

Our recommendation for the best dry aged beef: use meat from a young cow with an ordinary fat cover plus 
good marbling. 

6.

 

Hang the complete back on the hangers of your Steak Ager or put the individual cuts on the shelves. 

7.

 

Load capacity: max.2x half strip loins on the bone with a length of 0.5m, therefore you will need 2 hangers. 

8.

 

Load capacity with shelves: max.20kg individual pieces or cuts will fit on shelves. 

9.

 

When maturing individual cuts on the shelves, pay attention on a protective fat layer which prevents too 
much wastage and if possible let it mature on the bone. Ideal size approx.2-4 kg / cut. 

10.

 

Please wear protective gloves at each contact with the meat, DON’T touch the meat without gloves! 

11.

 

The perfect maturing time is between 25-28 days, but more than 4 weeks is also possible. 

 

Temperature Setting 

Important: The LED display is the actual temperature and humidity in the cabinet 
 
The temperature settings are pre-set at the factory as follows. In the event of a power interruption, all previous 
temperature settings are automatically erased and it will revert to the preset temperature settings. 
The electrical board of all models comes with memory function. 
 
It is important to understand that there is a difference between the temperature inside the Steak Ager and 
the temperature shows on display panel: You will need to wait approximately 12 hours before noticing the 
effects of temperature adjustment if the steak ager with full loading. 
 
Once the temperature is set, please don’t adjust it frequently. The thermostat will maintain the temperature 
inside the Steak Ager within a +/- 2°C range. But the thermal inertia of the Steak Ager and the glass is such that 
within this temperature range, the actual temperature of the Steak Ager will only fluctuate 0.5°C to 1°C. 
 

 

Содержание 7525 Series

Страница 1: ...Dry Age Cabinets 7525 Series User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi ...

Страница 2: ...ak Age 7 Open angle size drawings 9 Radiator System Description 10 Turn On Your Steak Ager 10 Security Lock 10 Operating Noises 11 Start Tips 11 Temperature Setting 11 Temperature Display Board Operating Instruction 12 Defrost System 14 Removing Shelf 14 Humidification System Description 14 Instructions For Adding Water and Replacing Absorbent Cotton 15 Reversibility Of The Door 19 Door timeout al...

Страница 3: ...red goods or spoilage Furthermore the appliance is not suitable for use in hazardous areas Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Notices in Operating 1 Children 3 8 years old are not allowed to take or place things from the Steak Ager 2 Opening the door for a long time may cause the temperature of the Steak Ager to rise significantly 3...

Страница 4: ...bustion supporting sprays 14 If the power cord is damaged in order to avoid danger non original professional authorized personnel or personnel with professional licenses may not repair and replace the product please contact the supplier immediately Danger 1 Pay attention to the danger that children may be trapped in the box 2 Do not let children operate the product alone 3 Do not use electrical eq...

Страница 5: ...ng instructions When installing the product must connect the grounding wire Please use the grounding power socket correctly to prevent the leakage of the wire and reduce the risk of electric shock The Steak Ager is equipped with a grounded power cord Improper installation of grounding may cause electric shock If you have any questions about the grounding installation information please consult a p...

Страница 6: ...st 5 days after slaughter 4 We recommend the best cooked beef use young beef with fat and marbled 5 Hang the whole piece of meat on the rack or put the cut pieces on the shelf Installation Guide 1 Built in Steak Ager are front venting but are not designed to be fully integrated behind a joinery door 2 Please follow the installation diagram when installing built in Steak Ager No less than the minim...

Страница 7: ...SA VI120SA VI180SA can be free standing installation or built in installation For specific installation dimensions please refer to the following embedded installation diagram Note The appliance must be positioned so that the plug is accessible after installed 7525 0100 7525 0105 ...

Страница 8: ...8 www combisteel com 7525 0110 ...

Страница 9: ...9 www combisteel com Open angle size drawings 7525 0100 7525 0105 7525 0110 ...

Страница 10: ... pressing on the power button for a few seconds When you use the Steak Ager for the first time or restart the Steak Ager after having it shut off for a long time there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout This is normal and it is due to the length of the activation time Once the Steak Ager is running for a few hours every...

Страница 11: ...eat can be used but for a maximum of 14 days please remove foil 5 Our recommendation for the best dry aged beef use meat from a young cow with an ordinary fat cover plus good marbling 6 Hang the complete back on the hangers of your Steak Ager or put the individual cuts on the shelves 7 Load capacity max 2x half strip loins on the bone with a length of 0 5m therefore you will need 2 hangers 8 Load ...

Страница 12: ...e on 1 hour 2 Manual control The steak ager is power on Please press this button 3 seconds the UV light will be always on Please press light button 3 seconds again and then the UV light will turn off 3 When the UV light turn on the UV light will be closed when door is open and it will be on when door is closed Note The life of the UV lamp is 12 months Exceeding the service life will greatly reduce...

Страница 13: ... is power on If the UV light doesn t be turned on by human the UV light will turn on for every 24 hours The times will be 1 hour It means every 24 hours the UV light will be on 1 hour 2 Manual control The steak ager is power on Please press light button 3 seconds the UV light will be always on Please press light button 3 seconds again and then the UV light will turn off 3 When the UV light turn on...

Страница 14: ...e Steak Ager is not totally sealed fresh air admission is permitted through the drainpipe Notes During the refrigerating cycle heat is given off and disperses through the external surfaces of the Steak Ager Avoid touching the surfaces during those cycles Removing Shelf Shelf taking According to below instruction drawing to press one side of shelf limit pin extract and remove the shelf from the oth...

Страница 15: ...illing reminder function When the water tank is short of water there will be a buzzer prompt At the same time the display window will display E5 to prompt a water shortage fault When this fault occurs the lighting lamp will flash At this time it is necessary to add water manually The display panel E5 disappears automatically within 10 seconds after the water addition operation is completed and the...

Страница 16: ...ater and replacing absorbent cotton 7525 0100 add water manually The steps are divided into 1 2 3 4 steps 1 Uncover the water tank cover A according to the arrow 2 After opening the water tank cover you can see the water tank take out the water tank according to the arrow direction ...

Страница 17: ...e water tank After opening you can add water After adding water put it back into the product cover the water tank cover and complete the water adding operation 4 Replace the absorbent cotton Take out the water tank assembly and update the absorbent cotton according to the view ...

Страница 18: ... the machine must be turned off before operation 1 Place a 2L water box under the drain then unscrew the drain cover to drain according to the following view 2 2 Drain cover operation diagram Remove the display board and the water tank baffle according to the view operation and unplug the connecting wires and take overs connected to the fan water inlet pipe etc on the water tank ...

Страница 19: ...may need to rotate the door 180 degrees or symmetrically change the direction of the door according to the product s own configuration 2 The door may be irreversible depending on the type of handles of the steak ager or the door may need to be opened and replaced when ordering Warning To avoid accidents during the process of changing the door we recommend that you get assistance The glass door is ...

Страница 20: ...door shaft core 6 from the two ends of the top of the door Take out the door and set aside Drawing 2 5 Discharge the upper and lower door hinge 7 8 by M5 inner six angle screwdriver Tool 5 then to assemble the door hinge on the opposite side Drawing 3 and 4 6 Reverse the door 180 degrees then Install the door on the opposite side of the cabinet Drawing 5 7 Finally install the decorative nail and d...

Страница 21: ...se use the electric drill to drill the holes of the door a bit big in surface side in order to install the handle perfectly Meat Quality Recommendation The best meat recognized for Dry aging is rib eye on the bone It is always best to purchase from a dealer who sources their meat from a good quality abattoir The younger the animal the better the result It is always recommended to buy a piece of me...

Страница 22: ...ho should carry out an inspection of the circuit sealing system Similarly any intervention on the electrical circuit should be performed by a qualified electrician Note Any intervention performed by a non authorized technician We will lead to the warranty being considered as null and void Power Failures In the event of a power interruption all previous temperature settings are automatically preser...

Страница 23: ...r is not closed completely The temperature is not set correctly The door gasket does not seal properly The light does not work Not plugged in The circuit breaker tripped or a blown fuse The light is damaged The light is OFF Vibrations Please check whether the steak ager is on level ground The Steak Ager seems to make too much noise The rattling noise may come from the flow of the refrigerant which...

Отзывы: