Page | 46
Verve LED
9. “Lines In Print”
Problematic Parts
Reasons
Correction Steps
1.
Head Nozzles
Head nozzles are blocked
Clean the Print Head
2.
Feed Adjustments
Incorrect feed steps
Correct the feed steps using the
Calibration Wizard
3.
Head Alignment
Head alignment is incorrect
Refer to the Head Alignment
section
4.
Feed Motor
Feed Motor or Driver is faulty
Replace the Feed Motor or
Driver
10. “UV Lamp Not Working”
Problematic Parts
Reasons
Correction Steps
Power Supply
No Power Supply to the UV
Lamp
Check and correct the power
supply settings
UV Lamp Settings
UV Lamp settings are incorrect
Correct the UV Lamp settings
UV Lamp Control Board
UV Lamp Control Board is faulty Check and replace the UV Lamp
Control Board
UV Lamp
UV Lamp is faulty or aged
Check and replace it, if required
11.
“Negative pressure drop / not working”
Problematic Parts
Reasons
Correction Steps
Negative Pressure Switch
Negative
Pressure
switch
program is disturbed or value is
incorrect
Check and replace it, if required
Ink
Ink overflowed from sub tank
and filled in reservoir
Vacuum
Vacuum is not generated by
pump (pump failure)
Check and replace the pump
Vacuum Pump
Vacuum pump connector is
loose
Tighten the Vacuum Pump
connector
Ink/Air Tube
Any
ink/air
tube
having
leakage/cut/loose
on
fitting
joints
Check and replace it, if required