Page | 30
Verve LED
Setting Procedure
–
Negative Pressure Control Board
Step 1:
a)
Enter setting mode
→
Press “ESC”
→
Number “13.2” will flash, this is setting 1.
b)
Press “ESC” again
→
& number 23.33 will flash, this is setting 2
Setting 1:
is for White Min set value
Setting 2:
is for White Max set value
Setting 3:
is for Color Min set value
Setting 4:
is for Color Max set value
Note:
Max negative value should be higher than min value eg. Min value is -0.1 then max value should be
at least -0.15.
Step 2:
Click on the MOV to change the number you need change.
Note:
The flush number means current adjust one.
Step 3:
Use the ADD button to adjust the numbers.
Step 4:
Press the ENT button to save the setting.
Step 5:
Press the ESC switch again to go to the next setting value.
Setting Procedure
–
Pressure Display Meter
Set 1 - P Protection Value
Press the SET button for one second and set the value 1
–
P with “UP” and “DOWN” button.
Note:
2-P value should be bigger than current value.
Set 2-P Protection Value
Press the SET button again, it will redirect to 2-P
Set 2-P with the UP and DOWN button.