43-
Reference: Softkeys
Start End:
Press
1
to select where to start races with an even number of lengths. Press
2
to select
where to start races with an odd number of lengths. In each case, the options are near end or far
end, and pressing the number associated with each toggles between the options.
Clear Lanes Automatically:
Press
3
to choose between clearing and not clearing all of the time
and place information for the lanes automatically when the event or heat is changed after a race.
This allows the scoreboard to be clear for the start of the next race. This is a feature used most
often for championship level meets.
Option
4
toggles between showing and not showing start reaction times on the scoreboard. In
order for this option to work, you must have a relay judging platform installed. You must also
have option
8
activated in the
Hardware Setup
menu (page 44). This time will only be
displayed for the amount equal to the pad delay settings in the timing menu (page 44).
Option
5
allows you to select the primary finish method for the near end of the pool. Option
6
allows you set the far end. If you have a Pad finish the timer will always look for buttons as a
backup, and if you have a Button finish there is no other timer option for backup. These are
toggle functions and will switch back and forth between the available choices.
Press
7
to make the time on the scoreboard blink in the event of a record being broken. You must
have a record time stored in the system to operate this feature.
Option
8
toggles between posting and not posting intermediate place status (splits from the
touchpads) on scoreboard.
Hardware
Function:
Allows you to configure your System 6 internal speaker volume, screen backlight
intensity, whether or not to allow Setup information to be downloaded from a PC, and relay
judging method and details. Far end splits, start reaction times and LED Numeric Scoreboard
intensity are also controlled from this section. Generally, the speaker volume should be set to an
audible level.
It is very important that you set the proper relay judging method. Electrically the buttons and
Relay Judging Platform (RJP) are very different.
Operation:
Press
1
to set the System 6 internal speaker volume. In the prompt box, type
0
to
turn the speaker off,
1
for low,
2
for medium or
3
for highest volume and press
enter
.
Press
2
to select the System 6 screen backlight intensity. In the prompt box, type a number
between 1 and 9, with 1 being the lowest intensity. Press
enter
to activate your selection.
Press
3
to enable the Allow Remote Setup option. Pressing 3 toggles the setting between Remote
Setup allowed and Remote Setup NOT allowed. When allowed, this option lets you to edit some
setup information on a PC using meet management software and then upload that information to
your System 6 through com port 1. This is especially useful for setting up event sequences.