In-Sight 3400 Installation
4. Attach the female M12 connector of the camera cable to the remote head camera's male
M12 connector. Attach the male M12 camera cable connector to the In-Sight sensor's
CAM
CAUTION
Remove power from the In-Sight 3400 sensor before connecting or disconnecting
the remote head camera. “Hot plugging” the remote head camera can damage the
In-Sight sensor and/or remote head camera.
Figure 2-3: CAM Connection
5. Verify that the 24VDC supply is not receiving power, and then connect the power supply to
the 2-pin terminal plug on the Breakout Cable. Attach the Breakout Cable to the
24VDC
connector on the sensor (Figure 2-4).
Figure 2-4: Power Connections
CAUTION
Never connect voltages other than 24VDC. Always observe the polarity shown.