5. Powering up
5.1 Operating voltage and frequency.
The unit may operates at voltages ranges from 90 to 250VaC at a frequency of 50 or 60 Hz. It is not needed to effect any setup
procedures:
Reflection LEDko P
will automatically adjust its operation to suit any frequency or voltage within this range.
5.2 Connection to mains power
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent International standards.
Note: in case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3 X
1,5 ø external 10 mm, rated 300/500V, tested to 2 KV, operating temperature
-
40°C
+
180°C,
Coemar
cod. CV5311).
Connection to mains power
Reflection LEDko P
is equipped with two power connectors, one as input and one as output, which can be used to connect more
fixtures in series (no more than 16 units @ 230V or 8 units @ 115V.).
The max absorption of
Reflection LEDko P
is reported in the following table:
-230/240V 0,67 A constant during normal exercise.
-90V 1,76 A constant during normal exercise.
WARNING !
Never link more than 16 units at 230 V or 8 units at 90 V.
In the following figure you can see an example of series connection:
WARNING!
• The use of a thermal/magnetic circuit breaker is recommended. Strict adherence to regulatory norms is strongly
recommended.
• Reflection LEDko P should not be powered through a dimmer as this may damage the internal switching power supply.
• Prior to connecting the device to mains power, ensure that the mains characteristics are within the recommended range
for use with Reflection LEDko P.
• All cabling and connections should be carried out by suitably qualified personnel.
Blu (CE) / Bianco(UL-ETL)
Blue (CE) / White (UL-ETL)
Marrone (CE) / Nero (UL-ETL)
Brown (CE) / Black (UL-ETL)
Giallo verde (CE) / Verde (UL-ETL)
Green yellow (CE) / Green (UL-ETL)