background image

English 

20 

 

 

11. Maintenance 

 

11.1 Periodic cleaning 

 
 

Lenses

 

Even a fine layer of dust can reduce the luminous output and alter the compactness of the beam. Regularly clean all filters and 
lenses using a soft cotton cloth, dampened with a specialist lens cleaning solution. 

Cleaning of the unit

  

Use a soft brush or a common vacuum cleaner or a source of compressed air for removing dust. For the cleaning of the housing 
use a soft cloth and a non-aggressive cleaner. Check that the internal fans and heat exchanger must be perfectly clean. 

11.2 Periodic controls 
 

Check the correct working of the mechanical parts and, if needed, replace them. Make sure the projector is not mechanically 
damaged. If necessary, replace the worn parts. 

Electrical components

 

Check all electrical connections, in particular for correct grounding and correct attachment of all extractable connectors. Press the 
connectors if necessary and reposition as before. 
 

11.3 Fuses: 

 

Reflection LEDko P

 has an automatic fuse that in most cases does not need to be replaced. 

12. F.A.Q. and answers  

 
The following list shows common issues that may be simply solved. If issues persist, the unit must be repaired by qualified 
personnel or just contact your Coemar service near you. 

Question 

Possible cause 

Suggested solution 

Reflection LEDko P

 does not power on. 

-

Projector not powered on:  

 

1-Make sure the power cord is plugged in 
or test the input voltage. 
 

Reflection LEDko P

 does not answer to 

DMX signal. 

DMX signal may not reach 

Reflection 

LEDko P

Inspect the cable connection, correct 
poor connections or inefficient repair or 
replace damaged cables. 
Check DMX address of the unit. 

Reflection LEDko P

 is not recognized by 

DR1 Plus. 

ID set to 0 or another unit in the chain is 
set with the same number. 

Set an ID number different from 0 and 
from any other unit in the chain. 

 

 

Содержание Reflection LedkoP

Страница 1: ...Instruction manual Manuale di istruzioni Ver 1 0 DIS151 ...

Страница 2: ...ring any technical enquiries with the utmost speed and accuracy Prendete nota nello spazio apposite dei dati relative al modello e al rivenditore del vostro Reflection LEDko P questi dati ci permetteranno di assistervi con la massima rapidità e precisione WARNING the security of the fixture is granted only if these instructions are strictly followed therefore it is absolutely necessary to keep thi...

Страница 3: ...owering up 11 5 1 Operating voltage and frequency 11 5 2 Connection to mains power 11 6 Control signal connections 12 6 1 Control signal connection by XLR5 plugs 12 7 Turning on the projector 12 7 1 DMX address of the unit 12 7 2 DMX functions 13 8 Display panel functions 14 8 1 Quick guide to menu 14 8 2 Rapid count 14 8 3 Main function menu FUNC 15 8 4 Measures and test s MEAS 16 8 5 User settin...

Страница 4: ...manual 3 The level of technology of Reflection LEDko P requires the use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essential for the proper functioning of the projector Never connect the fixture if there is no earth connection 5 Mains cables must not come into contact with other cables 6 Do not operate ...

Страница 5: ...characteristics Power 90 250 Vac 50 60Hz Autosensing Maximum current 0 67A 230 Vac 1 76 A 90VAC Power factor Cos ϕ 0 9 Light source wattage 140 W Maximum room temperature 35 C 95 F Weight 5 Kg 11 2 lbs main body Grado di protezione IP20 3 2 Dimensions ...

Страница 6: ...Yoke locking handle Interchangeable optic Profiler blade Gel frame locking spring Lens adjusting handles Multifunction LCD display MENU Key to access to menu or get back to previous page ENTER Key to confirm choices o access to submenues Key to scroll menu pages and increment values Key to scroll menu pages and decrease values Main power input Main power output to power further units DMX 512 signa...

Страница 7: ...o free the cap itself set the optic s flange tilted about 60 Insert the optic s flange into the body s receptacle and turn the optic 60 until it is firmly assembled to the projector body free to rotate but not free to detach itself from the body Ensure the optic to the body by tightening the two screws previously loosened ...

Страница 8: ... 4 3 Safety chain When hanging Reflection LEDko P it is recommended to use a safety chain as required by current legislation The safety chain must pass through the handles of the unit and then attached to the structure If using steel cables and chains not Coemar s production make sure they are suitable to support the weight of the unit according to normative UL ETL required the weight of 6 complet...

Страница 9: ...ich can be used to connect more fixtures in series no more than 16 units 230V or 8 units 115V The max absorption of Reflection LEDko P is reported in the following table 230 240V 0 67 A constant during normal exercise 90V 1 76 A constant during normal exercise WARNING Never link more than 16 units at 230 V or 8 units at 90 V In the following figure you can see an example of series connection WARNI...

Страница 10: ...signal has not been received Check the connection cable and the mixer functioning 7 1 DMX address of the unit Each projector can use up to 5 address channels for its complete operation and is controlled by a DMX 512 signal for further information see section 7 2 DMX functions DMX addressing When powered up initially each projector will show A001 which indicates DMX address 001 for example A second...

Страница 11: ... control frequency tuning 2000Hz LED control frequency tuning 2500Hz LED control frequency tuning 3000Hz LED control frequency tuning 3500Hz LED control frequency tuning 4000Hz stop strobe random strobe effect with variable speed from slow to fast non syncronised colors 5 special functions step 600 Hz park no effect LCD display off LCD display on LED control frequency tuning 1000Hz 4 strobe no eff...

Страница 12: ...selection 8 1 Quick guide to menu In order to access the functions just press the menu button press the key or to scroll pages To select the desired function press enter key 8 2 Rapid count By the display panel of Reflection LEDko P It is possible to quickly change the various numbers displayed for the different functions in the following 3 manners 1 Pressing the or buttons will cause the count to...

Страница 13: ...r 5 to unlock RVRS HOLD AA VV ON OFF Store DIMMER STROBE 0 255 0 255 D MAX RESE DFSE Disables the adjusting of the leds setting them at maximum output It permits the reset of the unit Keeping pressed ENTER and MENU at the turning on of the unit It allows to access ALIG features It restores all the settings at default value excepting of led settings and hour meter ON OFF enter SURE LED AUTO allows ...

Страница 14: ... value called RATE frequency of signal updating in milliseconds It shows the error message of the alarm in progress It shows the luminous efficiency of the LEDs M1234 It shows the led s life values in hours LIF R led module life resettable LIFE life of total modules installed on the unit since now not resettable UNIT life of the projector It shows the led s emission frequency It may be useful if f...

Страница 15: ...h its own unique identity number ID WARNING If you set as identification number 0 Reflection LEDko P will not be recognized by DR1 and DR1 Plus Never assign the same ID to two or more units of a same DMX line This causes the failure of the system DR1 and DR1 Plus will display an error message For more information see the manual for DR1 or DR1 Plus 8 7 Electronic alignment of the leds The display p...

Страница 16: ...mode is only achievable by connecting the DMX signal by keeping pressed MENU and ENTER keys during reset for 10 seconds MIN channel 1 MAX channel 1 MIN channel 2 MAX channel 2 MIN channel 3 MAX channel 3 MAX channel 4 MIN channel 4 LEDs of channel 1 alignment at minimum intensity LEDs of channel 1 alignment at maximum intensity LEDs of channel 2 alignment at minimum intensity LEDs of channel 2 ali...

Страница 17: ... function properly Check the DMX address indicated on the display and the number of channels generated by the mixer control We recall in this connection that some controllers do not generate all the 512 channels 10 Accessories and spare parts Reflection LEDko P is a very versatile fixture optional accessories for its customization are available under request Coemar order code Description AFO9305 F...

Страница 18: ...unding and correct attachment of all extractable connectors Press the connectors if necessary and reposition as before 11 3 Fuses Reflection LEDko P has an automatic fuse that in most cases does not need to be replaced 12 F A Q and answers The following list shows common issues that may be simply solved If issues persist the unit must be repaired by qualified personnel or just contact your Coemar ...

Страница 19: ...ppliers have been checked and are produced in compliance with the Directive in question Reference Title 2004 108 EC Directive of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC EMC 2006 95 EC Directive of the European Parliament and the Council of 12 Dec...

Страница 20: ...2 A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modifications without notification ...