2
Installing the Frame
2-8
HPF-9000 PRODUCT MANUAL
HPF9000-OM (V1.8)
Reference Loop Connections
(See Figure 2-5 and below.) A looping BNC pair is provided for a frame
REF 1
loop and a
REF 2
loop. Connections for the reference inputs are shown
below.
Power Supply Removal/Installation
Your frame is standard-equipped with power supply PSU1 and, optionally,
also PSU2.
Either supply is hot-swapable, and is removed by pulling the supply from the
frame by its handle. Install a power supply by aligning it with its mounting
slot and pushing the supply into the chassis until it is firmly seated.
Network Controller Card Removal/Installation
(See Figure 2-6.) As viewed from the card cage front, the Network Controller
Card occupies a reserved slot and is retained by a screw located at the bottom
front of the card. Loosen the retaining screw to allow card removal. Reverse
this procedure to install and lock the card in its slot.
Figure 2-6 Network Controller Card
REF 1
LOOP
REF 2
LOOP
Note: Looping reference connectors can receive
ref input on either connector of the looping
pair. Unless daisy-chained to another
node, an open connector here must be
terminated into an appropriate 75
Ω
terminator.
Network Controller Card
Setup DIP Switch
Card Retainer Screw
Содержание HPF-9000