HPF9000-OM (V1.8)
HPF-9000 PRODUCT MANUAL
2-7
Installation and Setup
Installing the Frame
Cable Connections
Power Connections
(See Figure 2-5.) The frame is equipped with an IEC power input receptacle
at the left and right sides of the frame rear.
1.
Connect supplied power cords to suitable AC power outlet.
Note:
• The left receptacle serves the redundant power supply (PSU2) position. Use
this connector only if frame is equipped with a redundant power supply.
• If redundant power supply PSU2 is installed, it is recommended to use a
facility AC receptacle that is on a separate circuit than that used for standard
power supply PSU1. This can help ensure power source redundancy.
Figure 2-5 HPF-9000 Rear View
2.
Each power supply is equipped with its own power switch (located on
the front of the power supply). With the switch set to the up position, the
power supply is turned on (as verified by the green LED adjacent to the
switch).
Network Connection
(See Figure 2-5.) Connect RJ-45 Ethernet network cable to rear panel
Ethernet connector. When the frame is powered, connectivity is shown by
illuminated indicator on Ethernet receptacle.
Note:
The frame Network Control Card must be configured to properly communi-
cate with the card remote control network (DashBoard and/or OGCP/
WinOGCP devices). Refer to Setting Up Network Remote Control (p. 2-11) for
procedure.
Primary Power Supply
(PSU1) IEC AC
Line Connector
Dual Looping
Reference
Connectors
Network
Ethernet
Connector
Redundant Power Supply
(PSU2) IEC AC
Line Connector
Card Rear I/O Modules