R e f e r e n c e s w i t c h
Next, please check the function of the reference switch. If the switches are not actuated, i.e. the axes
are within the normal travel range, the indicator lights "Ref." On the diagnostics page must be off.
You have to get started if you operate the switches by hand. For inductive switches you have to
hold a piece of metal in front of the switch, for reed switches a magnet.
Now it must be checked whether the directions of rotation of the drive motors are correct.
Go to the page "Setup". When pressing the arrow buttons, the associated axis must move in the
right direction. Depending on the position of the machine and the line of sight of the operator, the
actual direction (front / rear, right / left) may differ from the direction of the arrows. However, the
coordinate display counting mode must be up when the tool moves away from the home switch and
vice versa. With the Z axis, the tool moves up, that is, away from the workpiece when the
coordinate display counts up.