10.11.2018
With tool le ngth sensor
To perform the length measurement automatically after every tool change, you must first install the
survey macros as described in Chapter 27 "working with hight probe" After this, the position of the
button must still be entered in the machine parameters, so that the controller knows where the
length sensor is, what height it has, and at what speed it can be approached.
The parameters # 951, # 952 and # 960 to # 964 are used for this purpose. First enter the X and Y
position where the button is mounted on the machine table. The safety position is approached after
the measurement. This should be somewhere in the distance next to the button. This prevents the
probe from being damaged if, after a measurement, a program is started which moves as the first
movement with the Z axis all the way down.
The "offset Z-axis" (# 962) can later be adjusted so that the measured tool length corresponds to a
dimension (in principle arbitrary but verifiable), for example the length of the part of the tool that
protrudes from the collet. The exact value is actually insignificant, since only the difference in the
length of the old and the new tool is relevant when changing tools. If a different offset is entered, all
tools are measured longer or shorter, but the relevant length differences when changing tools remain
the same.
Enter the appropriate values for your machine and save it. Remember to check the function of the
signal input before using it for the first time by pressing the probe manually and observing the
response of the input on the diagnostics page.