Clore Automotive Pro-Logix PL2410 Скачать руководство пользователя страница 6

BATTERY CHARGING SETTINGS
Upon making a proper battery connection (see Section 

F or G as applicable), plug AC power cord into an AC 

receptacle. All unit LEDs will light momentarily, then only 

the LEDs corresponding to charging settings should stay 

lit. The charger is now in Standby Mode.
If an ERROR Indicator LED lights, disconnect from AC 

power supply immediately and determine the cause of the 

alarm. The POLARITY light indicates reverse polarity error 

connection, while the ERROR light indicates the detection 

of a battery fault, such as a shorted connection. 
To charge a battery:
 1.   Choose a battery voltage charge setting. The default 

setting is the 12V mode, which will apply to most 

charging applications. To charge in 24V mode, push 

the voltage setting button until the “24V” LED is lit.

 2.     Choose a battery type setting. To charge Standard 

and Maintenance Free Flooded Acid batteries, push 

the Battery Type button until the “STD” LED is lit. To 

charge AGM batteries, push the Battery Type button 

until the “AGM” LED is lit. To charge Gel Cell, push 

the Battery Type button until the “GEL” LED is lit.

 3.   Choose a battery charging rate. Small batteries found 

in lawn and garden, motorcycle or ATV applications 

should be charged in the lowest possible charge rate 

setting.

 4.   Press the “CHARGE” button and the charging 

indicator LED will light. The charger will automatically 

commence and complete the charging process. If you 

press the “CHARGE” button at any point during the 

charging sequence, the charger will stop charging and 

return to Standby Mode.

  

Note: If the ERROR LED lights, disconnect from AC 

power immediately and determine the cause of the 

alarm.  See Additional Features for a list of conditions 

that might cause this warning. If “Ohc” is shown 

on the display, the charger has entered overheat 

protection mode. See Additional Features for details.
Note: The charger is designed to protect against faults 

and shorts (see Battery Charger Features). If the 

battery to be charged has a open circuit voltage of 

less than 1V, the charger will indicate a fault. If, after 

unplugging unit, checking connections and verifying 

all settings, you determine the problem causing the 

“fault” condition is battery voltage below 1V, you can 

override the charger’s protection by holding down the 

“CHARGE” button for 3 seconds. The charger will 

commence the charging sequence and, assuming 

these are no other hindrances that caused the fault 

indication, will complete the charging process and 

automatically turn off when the battery has reached 

full charge.

   5.  When the battery approaches full charge and enters 

the Completion Phase, the green CHARGING 

COMPLETE indicator will light and the CHARGING IN 

PROGRESS indicator will flash. At this point, if time is 

critical, the battery can be put into service if it will be 

used in a charging situation, such as in a vehicle that 

that will be used immediately. To reach a true 100% 

state of charge, the charger should stay connected 

until the charger reaches the Rest Phase, when only 

the green CHARGING COMPLETE is lit.

  6. When you are finished with the charging process, 

      disconnect AC power cord from AC outlet, then 

      disconnect DC leads from vehicle ground (if charging 

      with battery in vehicle) and battery in the reverse 

      sequence of the connection procedure.

OPERATING INSTRUCTIONS

H

Battery Voltage Indicators

Battery Type Indicators

Battery Rate Indicators

Display

Charging 

Indicator

Charge 

Complete 

Indicator

Error Indicator

Start/Stop Charging Selector

Display Info Selector

Display Info Indicators

Reverse Polarity Indicator

Battery Volts Selector

Battery Type Selector

Charge Rate Selector

STATUS CENTER

CONTROL CENTER

CHARGING IN PROGRESS

CHARGING COMPLETE

POLARITY

ERROR

VOLTS

12V

STD

2A

24V

AGM

6A

GEL

PWR

10A

TYPE

RATE

% CHARGE

VOLTAGE

CHARGE

1

2

3

-LOGIX 

TM

PL2410

Содержание Pro-Logix PL2410

Страница 1: ...ted when vinyl clothing is rubbed Review all cautionary material on the SOLAR Battery Charger and in the engine compartment Always wear eye protection appropriate protective clothing and other safety...

Страница 2: ...s if the Charger was plugged into an AC outlet Use extreme care while working within the engine compartment because moving parts may cause severe injury Read and follow all safety instructions publish...

Страница 3: ...osive gases during normal battery operation For this reason it is of utmost importance that each time before using your charger you read this manual and follow the instructions exactly b To reduce ris...

Страница 4: ...sconnect DC output clips only after setting any switches with an OFF position to OFF and removing AC power cord from electric outlet Never allow clips to touch each other 2 When hooking up charger att...

Страница 5: ...ITIVE POS P battery post usually has larger diameter than NEGATIVE NEG N post 4 Determine which post of battery is grounded connected to the chassis If the negative post is grounded to the chassis as...

Страница 6: ...ection mode See Additional Features for details Note The charger is designed to protect against faults and shorts see Battery Charger Features If the battery to be charged has a open circuit voltage o...

Страница 7: ...s beneficial for the long term health of the battery BATTERY RECONDITION MODE During the Energizing Phase if the charger detects the presence of battery sulfation it will activate this mode If this oc...

Страница 8: ...reverse connections POLARITY LED will light on control panel and power will not be sent to output cables if a reverse connection is sensed BATTERY FAULT PROTECTION Guards against excessively charging...

Страница 9: ...ights which vary from state to state F FOR WARRANTY OR SERVICE M If this product fails within the warranty period return it to your dealer for an exchange A valid dated sales receipt is required to ob...

Страница 10: ...Manual Del Usario INSTRUCCIONES IMPORTANTES DE SEGURIDAD LEA ESTO PRIMERO A PL2410 Cargador de bater a...

Страница 11: ...Y IMPORTANTE QUE ANTES DE USAR SU CARGADOR LEA ESTE MANUAL Y SIGA ESTAS INSTRUCCIONES AL PIE DE LA LETRA b Para reducir el riesgo de explosi n de la bateria siga estas instrucciones y las indicaciones...

Страница 12: ...n de apagado off y de haber retirado el cable de corriente continua del recept culo Nunca permita que las mordazas se toquen entre s 2 Para conectar el cargador coloque una mordaza en la bater a y la...

Страница 13: ...A DE LA BATERIA SE PUEDE OCASIONAR UNA EXPLOSION PARA EVITAR EL RIESGO DE CHISPAS CERCA DE LA BATERIA 1 Coloque el cable de CA y de CC de modo que no sea da ado por la cubierta del motor puerta o part...

Страница 14: ...advertencia consulte Caracter sticas adicionales Si se observa Ohc en la pantalla el cargador ha entrado en modo de protecci n contra sobrecalentamiento Consulte Caracter sticas adicionales para ver...

Страница 15: ...la bater a se incrementa a un nivel m s normal y resulta beneficioso para el buen estado de la bater a a largo plazo MODO DE REACONDICIONAMIENTO DE LA BATER A Durante la Fase de activaci n si el carga...

Страница 16: ...una conexi n inversa el LED de POLARITY se encender en el panel control y los cables de salida no recibir n energ a PROTECCI N CONTRA FALLAS DE BATER A Protectores contra la carga excesiva de bater as...

Страница 17: ...y puede ser que le correspondan otros derechos que var an de estado en estado GARANTIA LIMITADA L PARA LA GARANTIA O ATIENDE M Si el producto falla dentro del per odo de garant a devu lvalo a su distr...

Страница 18: ......

Страница 19: ...Manuel De L utilisateur CONSIGNES DE S CURIT IMPORTANTES LIRE EN PREMIER A PL2410 Chargeur de batterie Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada...

Страница 20: ...NORMAL LES BATTERIES PRODUISENT DES GAZ EXPLOSIFS POUR CETTE RAISON IL EST EXTREMENT IMPORTANT DE LIRE CE MANUEL ET D EN SUIVRE LES CONSIGNES AVANT CHAQUE UTILISATION DU CHARGEUR b Pour r duire les ri...

Страница 21: ...au dessus du sol 1 ATTENTION Ne brancher et d brancher les pinces de sortie c c qu apr s avoir plac tous les interrupteurs sur Arr t et d branch le cordon d alimentation du secteur Ne jamais mettre l...

Страница 22: ...POUR R DUIRE LES RISQUES D TINCELLES PR S DES BATTERIES 1 Positionner les cordons c a et c c de mani re viter qu ils ne soient endommag s par le capot les porti res ou les pi ces en mouvement 2 Rester...

Страница 23: ...chargeur est entr en mode de protection contre la surchauffe Consultez les fonctionnalit s suppl mentaires pour plus de d tails Remarque Le chargeur est dot d une protection contre les pannes et cour...

Страница 24: ...u fur et mesure que la tension de la batterie atteint un niveau normal et est b n fique pour la sant long terme de la batterie MODE DE RECONDITIONNEMENT DE LA BATTERIE Pendant la phase de mise sous te...

Страница 25: ...que les composants internes du chargeur auront refroidi ce qui peut prendre 5 20 minutes voire plus Assurez vous qu il y a suffisamment d espace autour du chargeur pour la ventilation et que rien n o...

Страница 26: ...so Esta garant a otorga derechos legales espec ficos y puede ser que le correspondan otros derechos que var an de estado en estado GARANTIE LIMIT E L POUR OBTENIR DES SERVICES SOUS GARANTIE M Si ce pr...

Страница 27: ......

Страница 28: ...duct contains chemicals including lead known to the State of California to cause cancer birth defects and other reproductive harm Wash hands after handling 2015 Clore Automotive Operator s Manual Batt...

Отзывы: