Содержание TIM-1000

Страница 1: ...User Guide TIM 1000 Tracking Intelligent Microphone...

Страница 2: ......

Страница 3: ...Clockaudio Ltd All rights reserved Audinate the Audinate logo and Dante are registered trademarks of Audinate Pty Ltd Disclaimer This User Guide is written for users of the TIM 1000 Intelligent Track...

Страница 4: ...Page ii of vi V1 4 2019 09...

Страница 5: ...c 7 Only use the attachments supplied specified or recommended by Clockaudio Assurez vous que les instructions de s curit suivantes sont suivies Si le produit est r dit une autre partie assurez vous q...

Страница 6: ...oduit ne contient aucune pi ce r parable par l utilisateur Caution Unauthorised maintenance repair or the use of non approved replacements may affect the equipment specification and invalidate any war...

Страница 7: ...r up sequence 12 4 Feature Description 13 5 Understanding the GUI and Features 14 5 1 Passwords 14 5 2 Home Tab 15 5 2 1 Tracking 15 5 2 2 Noise Suppression 15 5 2 3 APT Adaptive Proximity Tracking 15...

Страница 8: ...ION Version 28 11 4 DEFAULTS Defaults 28 11 5 STS Set TS State 29 11 6 GTS Get TS Status 29 11 7 STSB Set TS Brightness 30 11 8 GTSB Get TS Brightness 30 11 9 SRGB Set RGB State 31 11 10 GRGB Get RGB...

Страница 9: ...applications Designed from the ground up and integrating seamlessly with Dante and AES67 networks third party controllers TIM 1000 offers a host of unique features that allows deployment flexibility a...

Страница 10: ...00 comes in a single carton This user guide and cardboard template for cutting hole in ceiling not shown below are also located in this carton TIM 1000 cable safety harness TIM 1000 top packaging foam...

Страница 11: ...n two cartons This user guide is located in Carton 1 TIM 1000 metal bracket TIM 1000 top packaging foam cover TIM 1000 trim ring TIM 1000 product TIM 1000 bottom packaging foam cover Contents of Carto...

Страница 12: ...Placez le gabarit fourni sur la dalle de plafond si n cessaire faites un 240mm 9 4 trou puis coupez de mani re appropri e 2 Insert an M4 eyebolt into one of the standoffs on the back of TIM 1000 Ins...

Страница 13: ...s curit afin qu il n y ait plus de jeu 7 Screw the four screws into the ceiling cover This rotates the fixing clips and clamps TIM 1000 to the ceiling Vissez les quatre vis dans le couvercle du plafon...

Страница 14: ...oteau 3 Feed the Shielded RJ45 Cat5e cables through the pole so that the RJ45 connectors appear through the bottom end Dante cable has to be connected to PoE control cable does not need to be PoE conn...

Страница 15: ...e picot de la face avant du TIM 1000 avec la bague de finition et attachez le doucement 7 Feed TIM 1000 s top cover through the pole connected to the ceiling Faites passer le couvercle sup rieur du TI...

Страница 16: ...r le verrouiller en place 11 Connect the other end of the shielded Cat5e cable to the appropriate network switches Connectez l autre extr mit du c ble blind Cat5e aux commutateurs de r seau appropri s...

Страница 17: ...ol port 2 CTRL 2 attach a shielded Cat 5e cable to the control port CTRL 1 on the second unit If multiple units need to be connected to cover a large area then repeat the process of connecting CTRL 2...

Страница 18: ...len dans le trou 2 Gently prise out the Trim ring out taking extra care where the ring is clipped in tight Soulevez d licatement la bague de finition en faisant tr s attention lorsque la bague est ser...

Страница 19: ...rez les c bles PoE et de contr le 3 6 2 Uninstallation of TIM 1000 Pole Mount 1 Rotate the TIM 1000 s top cover anti clockwise and lift up Faites pivoter le couvercle sup rieur du TIM 1000 dans le sen...

Страница 20: ...s tirez le boulon 3 7 TIM 1000 Power up sequence When a PoE cable from a live PoE network switch is applied to TIM 1000 s PoE port the unit powers up indicating the following sequence 1 The LED ring t...

Страница 21: ...ppropriate tab Featuring adjustable Adaptive Proximity Tracking APT technology TIM 1000 tracks the person or sound source within the room automatically and equalises the levels of the sound sources Th...

Страница 22: ...propriate password will have to be re entered The GUI is split into 3 sections Section 1 has the Clockaudio logo Generic product name TIM 1000 Product name that will appear to the control system e g D...

Страница 23: ...applied to the sound source that is further away to ensure that the sound levels of the quietest one to the loudest one in the room are kept consistent 1st stop When this stop is selected the quieter...

Страница 24: ...tom the panel s display changes from white to a darker shade of grey Brightness can be varied from 100 maximum brightness down to 16 with its value displayed at the bottom of the intensity panel As th...

Страница 25: ...s via DHCP or being set with a Static IP When Obtain an IP address automatically radio button is checked TIM 1000 requests a DHCP server to obtain the address For this mode there has to be a DHCP serv...

Страница 26: ...ing the older version Latest software versions will be available from the www clockaudio com under TIM 1000 5 3 6 Advanced controls Two buttons are displayed here Change password Change password allow...

Страница 27: ...ck on change password The change password pop up window with radio buttons will appear Click on the Home or Advanced tab to set the password for the appropriate tab Click on the appropriate tab and ch...

Страница 28: ...he second device You still have to run an independent cable to connect the second unit s Data port to the Dante network 6 2 Factory Defaults Reset Switch In the event of forgetting the passwords for t...

Страница 29: ...then TIM 1000 will attempt to contact the appropriate server to look up and set the time If the passwords of the Home and or Advanced tab are forgotten not available or have been lost then it s possib...

Страница 30: ...d the slave units listen on the IP ports of the master unit for commands going to the master Any relevant commands e g change of light colours Tracking ON OFF Noise suppression ON OFF APT settings and...

Страница 31: ...nit a couple of times to ensure that the fault persists If fault persists please contact your dealer for repair 3 TIM 1000 not showing up on Dante network Check the network settings for the Dante netw...

Страница 32: ...set Retained as set Retained as set Dante IP address DHCP Retained as set Retained as set Retained as set Product name TIM 1000 last six digits of Mac Address Retained as set Retained as set Retained...

Страница 33: ...er 2 Standard ports Connectivity Use a standard Shielded Cat5e or better Power supplied via PoE Voltage 42 57V DC 8W IEEE 802 3at 2009 Operating Temperature 0 to 40 degC Storage Temperature 20 to 60 d...

Страница 34: ...ollow the following rule COMMAND Space PARAM 1 Space PARAM 2 Space PARAM 6 CR Where COMMAND is the actual command sent to the device Space is a space character 20H from the ASCII Table sent to the dev...

Страница 35: ...set Identify on Ex 1 ID 1 CR Device response s The following response shall be received from the device Res 1 ACK ID 1 CR 11 2 FU Find Unit Definition The Find Unit command is used to permit a given u...

Страница 36: ...est firmware version Ex 1 VERSION CR Device response s The following response shall be received from the device Res 1 ACK VERSION x y CR Where x indicates the major version number and y the minor vers...

Страница 37: ...ACK STS 4 B 1 CR Blue LED set to ON for LED 4 only 11 6 GTS Get TS Status Definition The Get TS status command is used to retrieve the logic input output state of either ALL or a selected LED The data...

Страница 38: ...response s The following response shall be received from the device Res 1 ACK STSB 0 R 50 CR Res 2 ACK STSG 1 R 70 CR Res 3 ACK STSB 4 R 90 CR 11 8 GTSB Get TS Brightness Definition The Get TS brightn...

Страница 39: ...to 100 intensity on LED 1 Device response s The following response shall be received from the device Res 1 ACK SRGB 0 255 255 255 CR Res 2 ACK SRGB 1 128 0 255 CR 11 10 GRGB Get RGB State Definition...

Страница 40: ...o set APT to NORMAL Ex 1 APT 3 CR sets APT to NORMAL Ex 2 APT CR inquires status of APT Device response s The following response shall be received from the device Res 1 ACK APT 3 CR Res 2 ACK APT x CR...

Страница 41: ...Q 0 CR inquires EQ state of the LOW frequency setting Device response s Res 1 ACK EQ 0 4 CR Res 2 ACK EQ 1 10 CR Res 3 ACK EQ 0 x CR where x indicates EQ value of LOW frequency settings 11 14 NOISESUP...

Страница 42: ...meet the terms listed will incur a repair and carriage charge The product must be correctly installed and operated in accordance with the instructions supplied with the product Unauthorised modificat...

Страница 43: ...bsite www clockaudio com Corporate Headquarters Clockaudio Limited Wellington Gate Silverthorne Way Waterlooville Hampshire PO7 7XY United Kingdom Tel 44 23 92251193 Subsidiaries Clockaudio North Amer...

Страница 44: ......

Отзывы: