31
When Pendant 1 and Pendant 2
buttons are pressed together.
When the Red Help Button and
Pendant 2 button are pressed together.
515555157 – Help arrived mode
When help arrived mode is activated.
551555517 – Mobility/Inactivity
When CTC-1041RV makes Mobility
Timer Expired reporting.
If no sudden movement within 10
seconds
after
fall
detection,
an
inactivity code will be sent to Central
Monitoring Station.
555556558 - Panel Low battery / Battery
Not Connected
When CTC-1041RV is under Low
Battery or Battery Not Connected
status, the Green LED flashes every 2
sec with 2 short beeps every hour.
555551557 - AC Failure
When the AC power fails for more
than 10 sec, the Green LED flashes
every sec with a beep every 30 sec.
555553557 - AC Failure Restore / Panel
Low Battery restore / Battery Not
Connected restore
When the AC power failure status is
restored. .
When the Panel Low Battery status is
restored
When
the
Panel
Battery
Not
Connected status is restored.
515555559
-
Global
test
/
WTR
Supervision Failure
When CTC-1041RV reports Global
Test to monitoring Center.
When CTC-1041RV is unable to
receive the signal transmitted from the
Wrist Transmitter for a pre-set period
by Command #49.
555555559 - Periodic test report / Help
Arrived
When CTC-1041RV reports Periodic
test call to Monitoring Center.
When CTC-1041RV makes Help
Arrived reporting.
535555557 - WTR Supervision Failure
Restore / WS Emergency Restore
When the WTR supervision failure
status is restored.
When WS emergency status is
restored.
555555558 - Device Low Battery
When devices are under Low Battery
Status, the Green LED flashes every 2
sec with 3 beeps every hour.
555555558 - Device Low Battery Restore
When the device Low Battery status,
is restored.
155555517 - SD or CO emergency
When the Smoke Detector (SD) or
Carbon Monoxide Detector (CO) is
triggered.
355555517 - SD or CO emergency
restore
When the Smoke Detector (SD) or
Carbon Monoxide Detector (CO)
emergency status is restored.
FCC Statement
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference,
and
(2) This device must accept any interference
received, including interference that may cause
undesired operation.
Содержание CTC-1041RV