14
During two-way communication, you
can use DTMF command to switch the
communicating method. Please refer to
section
4.2. Alarm Activation
.
The first digit of Access Code must be
entered within 15 sec. Otherwise,
CTC-1041RV will disconnect the call
automatically.
To terminate the call, press DTMF (
9
)
or RESET BUTTON on CTC-1041RV.
If the 5-minute waiting period is up,
CTC-1041RV will automatically exit
this waiting mode and return to idle
mode.
Command #41 (Auto Answer for
Remote Programming) will not be able
to proceed during the 5-mins Call-
back time.
Command 39
Dialing Mode
This function is for you to select the dialing
method of your telecommunications.
There are two dialing methods available for
user:
Function Selection
Result
0
TONE
1
PULSE
Factory Default
is set
as (
0
),
Tone
.
Command 40
Set Access Code
The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
It consists of 4 digits and has been set to
(
1111
) as factory default. Before you set
your own Access Code,
(
1111
) must be
keyed in.
To set a new Access code; enter the
desired (
4-digit number)
in
Function
Selection
.
Command 41
Auto Answer for Remote Programming
CTC-1041RV can be programmed to auto
answer incoming phone calls after a pre-
set number of rings have been reached.
The number of rings range from (
00
) (no
auto answer) to (
32
) rings.
Function Selection
Result
(00)
OFF
(01) - (32)
ON
Factory Default is (
20
) Rings.
<
<
N
N
O
O
T
T
E
E
>
>
If
00
is selected, it means CTC-
1041RV cannot auto-answer the call
by ring count. If you want to do
Remote programming, please follow
the Remote Programming method
described in
System Conifuration, I.
Entering Programming Mode: 2.
Remote Programming Mode.
Command 43
Periodic Test Call
CTC-1041RV can be programmed to make
test calls periodically from (00) (no test call)
to every (1) - (7) or 30 days:
Function Selection
Result
(0)
OFF
(1) - (7)
1 - 7 DAYS
(8)
30 DAYS
Factory Default is set as (
0
),
OFF
.
<
<
N
N
O
O
T
T
E
E
>
>
Whenever programming mode is
accessed, CTC-1041RV will reset the
Periodic Test Call timer.
Periodic Test Call will only function
with telephone numbers assigned to
Digital
reporting method in
Command
20-24.
Содержание CTC-1041RV
Страница 1: ...c August 12 2013 ...