Installation Instruction
4.3 Installation Dimensions
All drawings and dimensions in this Installation Guide are a generic reference only. PV-ezRack
®
SolarRoof™ is to be optimized to suit specific conditions for each project and should be
documented in a construction drawing.
Major components of PV-ezRack
®
SolarRoof™ may be provided in section sizes and lengths
varying from those shown in this guide. The installation process detailed in this instruction guide
remains the same regardless of changes in component size.
If you need to do any on-site modifications or alteration of the system please provide marked up
drawings/sketches for Clenergy’s review, prior to modification, for comment and approval.
5. Installation Instruction
- Assess the number of modules in the vertical direction using the module height plus at
least 18mm between modules (please check the installation manual of the solar module
manufacturer);
- Assess the Number of modules in the horizontal direction using the module width plus 18 mm
(20 mm if using Universal Clamps) between the modules.
Note: The standard end clamp will also add 20 mm (except for dual end clamps) on each
side to the space required;
- Assess the horizontal spacing of the Roof Hooks;
- Assess the vertical spacing of the Roof Hooks = approx. 1⁄2 to 3⁄4 of module height;
- Always check the installation manual of the PV-Module you use in order to determine the
allowed fixing points on the module frame.