Apex Tool Group
P2291BA | 2020-05
25
9
EN
9.3.6 Set position submenu – only with
Linking enabled
9.3.7 Scanner submenu
TQ measurement
In this test function, after the start button
is pressed, the same calibration is carried
out as immediately before the start of a
rundown. For this, the tool must not be
tensioned!
Then, the tool starts with speed "0". The
torque is continuously measured and dis-
played until the start button is released.
Second line: Current torque.
Third line: Peak value, highest value
since the start button was pressed.
Angle encoder
The start button starts the tool at 30 % of
the maximum speed. After one revolution
of the output shaft (nominal angle 360°),
measured with the resolver, the tool is
stopped. During a fixed dwell time of 200
ms, any further angle pulses occurring
are traced. The total result is shown as
Actual Angle. If the test run is not termi-
nated by a monitoring criterion and the
batch result is greater than or equal to
360 degrees, it is evaluated and dis-
played as OK. Monitoring criteria are the
torque and a monitoring time.
If the torque exceeds 15 % of the calibra-
tion value (even during the dwell time), or
if the monitoring time of 4 seconds
expires, the test run is terminated with a
TQ>
or
TMAX
result. However, you spe-
cifically need to check whether the output
shaft has actually turned by the value
indicated (e. g. by placing a mark on the
spindle). If the angle reached by the out-
put shaft does not agree with the value
displayed, either the angle factor has
been entered incorrectly or the resolver is
defective.
Voltages
Second line: Current battery voltage. To
ensure high utilization potential, this volt-
age is monitored continuously during fas-
tening operation. If the voltage drops
below limit, a warning output on the tool.
Third line: Programmed value.
This can be changed using the control
(in
menu
Tool
)
.
Torque
T 5.57
T 8.23
Angle
A 360
OK
Voltage
V26.40
U19.00
Speed
The start button starts the tool at the
maximum speed.
Second line: Current output shaft speed.
Third line: Current torque.
Rotational speed measurement is based
on the angle information of the resolver. If
you release the start button, the tool
stops. As a safety function the torque is
monitored by the tool transducer. If it
exceeds 15 % of its calibrated value, the
speed measurement is terminated.
Selects the position to be used next.
You can skip the position.
You can select the position to be used
next using the function keys:
•
<F1>: Activate the previous posi-
tion.
•
<F2>: Activate the next position.
•
Press the start button or <F2> lon-
ger than 2
seconds to accept the select and
display the next menu item.
•
Press <F1> longer than 2 seconds
to delete the selection and exit the
menu.
Reset linking to position 1. The machine
operator can cancel Linking.
Deletes a previously read barcode and
activates a new read cycle.
Press the Start button or <F2> for longer
than 2 seconds.
Speed
RPM466
T 0.02
>Posit
Change
Positi
Select
Positi
2/6
>Posit
Reset
Positi
>Scann
Activa
Scanne