11.5 Reset tool
This key combination activates the
Service
menu. Here,
the tool can be shut off or reset to the delivery settings.
Note
The following will then be deleted:
•
the internal memory (programming)
•
the current fastening job
•
rundown data not yet transmitted to the control
Once selected, there is no way back to the current fastening job.
1.
2.
3.
4.
1. Press <F1>+<F2> at
the same time and hold.
2. Press start button 1×
and release.
1. Release <F2>.
2. Keep <F1> pressed and
continue with step 3.
1. Press <F2> 3× and
release.
2. Keep <F1> pressed and
continue with step 4.
1. Press start button 1x.
2. Release both buttons.
5. Switch off
5. Reset
1. Change to the Service menu with <F1>, <F2>.
Select within 60 seconds or else the tool with switch off:
Confirm with the start button and switch the tool off.
or…
2. Confirm with the start button and reset the tool to the
delivery settings.
<F1> <F2>
Start
<F1>
<F1>
<F2>
<F1>
Start
>Servi
Dis
Able
>Servi
Reset