34
P2291BA | 2020-05
Apex Tool Group
11
EN
No WLAN data
communication
between the
controller and tool.
WLAN settings are
different for control
and access point.
On the control sc
reen
Tool Navi-
gator > Utilities > System Settings
> Radio Frequency (RF) Configu-
ration LiveWire/CellCore
, check
whether the WLAN settings for
the tool agree with the settings for
the access points (network name,
encryption, network key).
On the control screen
Main Menu
> System Programming > Service
> TMA Configuration > Communi-
cation with Tool
, check whether
the WLAN settings for the tool
agree with the settings for the
access point (network name,
encryption, network key).
A filter for MAC
addresses is acti-
vated at the Access
Point.
Add the MAC address for the tool to the list of approved addresses at the
Access Point.
MAC adress of tool – see
•
Label above the battery
•
On the tool in the
Wireless Settings
submenu.
Port 4001 is dis-
abled by a firewall.
Configure the firewall such that the required IP/MAC addresses can use
port 4001.
The wireless chan-
nel at the access
point is outside the
range supported by
the tool.
To change the wireless channel setting at the access point to the right
wireless channel with respect to country code: EU 1–13; World 1–11 (see
Installation Manual P1894E).
Tool is already
assigned to another
control.
Check whether another control already has a connection to this tool. In
other words, another tool is using the same IP address.
IP address cannot
be pinged.
IP Address already
exists in network. In
this case, the tool
will not build up a
connection.
Check the physical connection (RSSI values).
Check the assigned IP address.
Occasional interrup-
tions in WLAN data
communication.
Distance between
the access point
and the tool is too
great.
1. Check the signal strength at the tool in the
Wireless Setting
submenu.
2. If necessary, reduce the distance between the access point and the tool.
The tool is already
assigned to another
control.
1. Check whether the tool (IP address) is also assigned to another control.
2. If yes, delete the assignment in the other control.
A tool can only be assigned to one control.
Excessive data traf-
fic on WLAN Net-
work.
Reduce data traffic on WLAN Network.
1. On the control screen
Basic
,
increase the
Initial Torque
.
2. On the control scr
een
Navigator > Advanced > Control-
ler > Trace Recording
, disable the
torque gr
aph data transmission.
1. On the control screen
Main Menu
> Application Builder > Settings >
Fastening Stages > Fastening
Stage # > Fastening Sequence
,
increase the
Initial Torque
.
2. On the control screen
Main Menu
> System Programming > Spe-
cial Functions > MWF
, disable the
torque graph data transmission.
a. ) Software-dependent measure. Discrepancy possible when using Custom Tool Software.
Problem
Possible cause
Measure for mPro400GC
(SW S816813)
Measure for mPro400S… (example
SW 816841)
a