14
P2291BA | 2020-05
Apex Tool Group
5
EN
See instruction manual for battery pack/instruction manual
for power module PM48.
5.2.6 LCD display
5.2.7 Wireless interface
The tool uses this wireless interface port for continuous
communication with the controller. This interface port is
used to transmit both the parameters and the rundown
results. Data transmission is possible in the
Active
,
Energy
saver mode
and
Standby
operating modes, but not possi-
ble in
Sleep
(see 8.2 Operating status, page 19). Program-
ming and setting up the wireless interface port are
described in the programming manual of the controller.
5.2.8 LiveWire Memory Chip (LMC)
To permit simple replacement of tools in production, a
replaceable LMC memory module is installed. When the
tool is switched on, the network settings are read from the
LMC chip and used to establish the WLAN connection.
When the tools are changed, the LMC has to be installed in
the new tool being used. Please refer to 7.4 Changing
LMC, page 17.
The following data are stored on the LMC:
The MAC address is defined by
Cleco
and cannot be
changed. The other data can be changed via infrared con-
nection of the tool to the controller.
Note
If the tool is operated with a 44 V/48 V power
supply for the first time, the maximum speed
in the self-identification data of the tool is
permanently increased.
In this is the case, note the following:
Use at least the LiveWire software ver-
sion S169251-123.
Adjust the speed parameters in the ref-
erence values to be able to use the
higher speeds.
At higher speeds, higher reaction
torques are to be expected. This can
lead to surprise effects and risk of inju-
ry.
Due to the higher kinetic energy at
higher speed, the shut-off point can be
passed over. Shut-off point adjustment
need to be checked.
Perform test tightening with the new
parameters.
-
Tightening behavior may change
and may require further adjust-
ments.
-
Tightening time changes. Adjust-
ment of process monitoring tmax
is necessary..
-
With changing power supplies, the
higher target speed with the bat-
tery pack 26 V can not necessarily
be achieved (
Δ
tmax).
To reset the maximum speed to the
value of 26 V operation, contact the
Apex Tool Group service department.
Communication
Required remote station
WLAN Standard IEEE
802.11ac/b/g/n
Access Point nach Stan-
dard IEEE ac/b/g/n
After the tool is switched on, it can take up
to 35 seconds until the communication is
active.
•
MAC address
•
Network name
(SSID)
•
Encryption
•
Network key
•
Use of the DHCP
server
•
IP address
•
Subnet mask
•
Gateway
•
Country-specific settings
•
Roaming settings
•
Channel selection
•
Network certifikates
•
API license