Initial operation
8.1 Carrying out the rundown
Ensure secure position of the power supply before starting
the tool. The tool is now ready for operation.
Press and release the start button: Rundown is exe-
cuted, the LCD display shows
Ready.
Types with wireless transmission continuously communi-
cate with the controller. The tool automatically receives the
parameters and, when the rundown is complete, automati-
cally sends the rundown results to the control system. Pro-
gramming and setting up the wireless interface port are
described in the programming manual of the controller.
Types without wireless transmission must be placed in the
tool holder when the rundown is complete. The rundown
results are transmitted and shown under the
Run screen
menu item.
8.2 Operating status
The following functions are available depending on the dis-
play:
The operating modes change in the following order.
This operating mode maintains the logic supply for up to
15 seconds during the battery pack change:
Warning
Risk of glove being pulled in due to rotating
machine parts.
Risk of fingers being crushed or lost.
Do not wear gloves when working with
this tool.
Operat-
ing status
LED display
LCD
display
Function
Active
Continuous light:
Red – Fasten-
ing NOK
Green – Fasten-
ing OK
On
screws
Data
transmis-
sion
a
After 1 minute idle time automatic switch to:
a. ) Times are default values and can be programmed in
the controller.
Energy
saver
mode
Green flashing
light
Off
Data
transmis-
sion
Automatic switch to the following after a
further 10 minutes:
Sleep Off
Off
Data
transmis-
sion not
possible
Manual change from
Sleep
to
Active
:
Press the start button fully down and hold it for about
1 second.
For manual deactivation of the tool, disconnect the
power supply.
Operating
status
LED display
LCD dis-
play
Stay alive
Red-green flasing light
alternately
Aus