Apex Tool Group
P2260JH | 2019-05
21
Installation – Local network
6
EN
Setting the access point via the integrated web interface
The configuration can be accessed via the integrated web interface using the IP address set above.
The settings made can be checked with a WLAN channel scanner, e.g.
NetSpot
.
The change of IP address was successful, the fol-
lowing dialog appears:
The IP address is only temporarily stored in the
access point. The IP address still has to be perma-
nently stored in the access point.
1. Start a web browser with the URL:
Apex Tool Group standard settings: http://
192.168.0.50
2. Log in:
-
User name
: admin
-
Password
: private
3. Select
Configuration > Network
and enter
the following data:
-
IP Address Assignment
: STATIC
-
IP Address
: 192.168.0.50
-
Network Mask
: 255.255.255.0
4. Confirm entry with <Apply&Save>.
5. Select
Configuration > WLAN Setting
and
enter the following data:
-
Country (regulatory domain)
: Germany
-
Activate WLAN Interface
: Enable
-
Outdoor mode
: Not Enable
-
WLAN band
: 5 Ghz (802.11 a/n)
-
Channel
: Channel will be assigned
6. Confirm entry with <Apply&Save>.
7. Select
Configuration > WLAN Interface
and
enter the following data:
-
Operation Mode
: Access Point
-
Network SSID
: Enter the network SSID
-
Security mode
: WPA2 PSK AES
-
Passkey
: Enter the password
8. Confirm entry with <Apply&Save>.