Installation – Local network
16
P2260JH | 2019-05
Apex Tool Group
6
EN
Minimum parameter setting
Setting individual parameters
Parameter
Value
Comments
Country code
Country (e.g.
Germany)
Select country in which the access point is in use.
IP address
Example:
192.168.0.50
The IP addresses for the access point, the controller and all tools
must be in the same subnet.
a) Either use the Apex Tool Group standard settings (IP
192.168.0.50) or enter an unassigned address.
b) For your own local networks, use the intended IP range
192.168.XXX.XXX.
Frequency
band
2.4 GHz or 5
GHz
Depending on the network structure, select a 2.4 GHz or a
5 GHz network.
SSID
LiveWire001
Choose the network name so that it can be unambiguously
assigned. Note upper and lower case.
Channel
1–13 or 36–
140
Auto
is not recommended.
Please refer to
6 Installation – Local network, page 14 for the assign-
ment of channels.
Not regional regulations when choosing the channel!
Security
Various security systems are available for use.
Choose a system according to your own requirements.
Admin pass-
word
The Apex Tool Group default password for logging in to the access
point is:
123456
.
Change this password to protect the access point against unau-
thorized access.
1. First refer to Settings on service PC,
2. Select the address
http://
192.168.0.50
in the browser of the ser-
vice PC.
→ The login mask for the access point
opens.
3. Enter login:
-
Name:
admin
-
Password:
123456