Front Hopper
[32]
H.3.S
Seed motor module
temperature
shutdown
Module
temperature has
exceeded the
value programmed
Motor speed very low
Excessive load applied to
motor which for a prolonged
time has caused the high
module temperature
H.4.S
Seed motor module
overload shutdown
Motor current
requirement
exceeded so
module shutdown
and motor
operation inhibited
Motor stalled
Excessive drag on the
metering unit requiring high
motor current
H.5.SF
Forward Speed
Failure (Seed & Fert)
Check wiring of forward
speed in alarmed connection
box.
Check for continuity between
pin 2A on MCM 1 (white wire)
and pin 2A on MCM 2
H.5.LR
Forward Speed
Failure (Left & Right)
Check wiring of forward
speed in alarmed connection
box.
Check for continuity between
pin 2A on MCM 1 (white wire)
and pin 2A on MCM 2
H.6.S
Motor has Stalled
Check for blockages in the
metering unit
Disconnect motor from
metering unit and ensure
both units rotate separately.
Check motor and gearbox.
Open and Close Finger
Switch/Area Cut Out to Reset
Alarm Criteria