Appendix A - Artemis Fault Codes
Code
Screen
Reason
Check?
N/A
High forward speed
Forward speed
exceeds the
maximum calculated
and displayed on the
RATE screen
Target application rate is as
required
Calibration factor is realistic
Adjust metering unit and
recalibrate which will
increase kg/rev factor and
therefore increase maximum
achievable forward speed
L.1
Low fan speed
Fan speed is below
the low alarm value
programmed
Fan’s actually operating
Hydraulic flow from tractor
Sensor & target functioning
and correct
PPR value programmed
correctly
L.2
High fan speed
Fan speed is above
the upper alarm
value programmed
Fan is actually operating
Sensor & target functioning
and correct
PPR value programmed
correctly
Hydraulic flow from tractor
L.3.SS
Seed level is low
(Seed only or Seed & Fert
drill, 1 metering unit per
product)
Seed level is actually low
Sensor is functioning
correctly
Wiring between sensor and
connection box is correct
Wiring between connection
box and CAN module is
correct
L.3.FS
Fert level is low
(Seed & Fert drill only, 1
metering unit per product)
Fert level is actually low
Sensor is functioning
correctly
Wiring between sensor and
connection box is correct
Wiring between connection
box and CAN module is
correct
L.3.SL
Seed level left is low
(Seed only drill with 2
metering units,
independent left & right
level sensors)
Seed level left is actually low
Sensor is functioning
correctly
Wiring between sensor and
connection box is correct
Wiring between connection
box and CAN module is
correct