30
© 2006 Directed Electronics—all rights reserved
features menu
The factory default settings are indicated in
bold
text in the table below.
FEATURE
DEFAULT - LED ON SETTING
LED OFF SETTING
NUMBER
(PRESS CHANNEL 1)
(PRESS CHANNEL 2)
1
Engine checking on
Engine checking off
2
Tachometer checking type
Voltage checking type
3
12 minutes run time
(1)
*
24 minutes (2)*, 60 minutes (3) run time
4
Flashing parking light output
Constant parking light output
5
Cranking time 0.6 sec.
(1)
Cranking time 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5),
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) sec.
6
Voltage check high level
Voltage check low level
7
Short Run (turbo timer): 1
(1)
min
Short Run (turbo timer) 3 (2), 5 (3), 10 (4) min.
8
Activation pulse: 1 (1)
Activation pulses: 2
(2), 3 (3)
9
Ignition/accessory output: Ignition
Ignition/accessory output: Accessory
10
Accessory state during wait to start: OFF
Accessory state during wait to start: ON
11
2nd status output: Normal
(1)
Rear defogger latched (2)/pulsed (3)
12
Diesel timer Wait-to-Start input
(1)
Timed 15 (2), 30 (3), 45 (4) seconds
13
Run Time (Timer Mode) 12 minutes
(1) 3 (2), 6 (3), 9 (4) minutes
14
Door Lock pulse duration 0.8 seconds
(1)
3.5 (2), 0.4 (3) seconds
15
Unlock output 1 pulse
Unlock output 2 pulses
16
Lock output 1 pulse
Lock output 2 pulses
17
Ignition unlock ON
Ignition unlock OFF
18
Ignition lock ON
Ignition lock OFF
19
Factory Alarm Disarm with unlock
Before Unlock (2)/remote engine start only (3)
20
Factory Alarm Disarm 1 pulse
2 pulses
21
Comfort Closure ON
OFF
*NOTE:
The number in parentheses indicate the number of times the LED will flash