How to order
AX4000T
Series
AX4000T
Actuator
(
)
D
Cable change
Note: "04" for cable
length 4 m
How to order
C
Mounting base
Note 4, Note 5, note 7
G
Dowel hole
Note 5, Note 6
E
Brake
note 7
H
Body surface treatment
Note 4
B
Driver type
Model no.
A
Size (max. torque)
D
Cable length
Note
Note on model no. selection
Note 1: Use the table below to select the appropriate driver.
Driver-power voltage table
Driver
Type
Model
TS type driver
Three phase and
single phase
200 20 to VAC
Single phase
100 115 to
VAC
AX4009T
Blank Note 2
J1
AX4022T
Blank Note 2
J1
AX4045T
Blank Note 2
J1
AX4075T
Blank Note 2
Note 2: Single phase 200 to 20 VAC is available for models with a torque of 45N•m or less.
Note : The cable is a flexible cable
Refer to page 5 for dimensions of the cable.
The body outlet cable is not a flexible cable.
Note 4: Select surface treatment and mounting base surface treatment with
C
and
H
. By selecting the optional electroless nickel plating treatment, you
can expect higher rust resistance compared to standard specifications.
Note 5: "P2" and "P" cannot be selected if "B" with blackened mounting base
or "BS" electroless nickel plating surface treatment mounting base is
selected for
C
Mounting base.
Note 6: Additionally machined sections such as dowel holes may not have a treated surface.
Note 7: Refer to the Option Table below and select required options.
Option table
AX4009T
AX4022T
AX4045T
AX4075T
Mounting base (B)
Mounting base (BS)
Brake
(EB)
F
Driver power voltage
Note 1
Symbol Descriptions
A
Size (max. torque)
009
9 N•m
022
22 N•m
045
45 N•m
075
75 N•m
B
Driver type
TS
TS type driver
C
Mounting base (can not be used with a dowel hole P2, P.)
Blank Standard (without mounting base)
B
With blackened mounting base
BS
Use with an electroless nickel plating table plane
treatment mounting base body surface treatment S.
F
Driver power voltage
Refer the driver-power voltage table on the left.
G
Dowel hole
Blank Standard (without dowel hole)
P1
1 on top
P2
1 on bottom (2 pc. on bottom for AX4009T)
P
1 each on both top and bottom (2 piece
on 1 pc. on top and bottom for AX4009T)
H
Body surface treatment
Blank Standard (Rotating section-blackened, fixed
section outside circumference-painted)
S
Rotating section: electroless nickel
plating, fixed section: nitrating
E
Brake
Blank Standard (without electromagnetic brake)
EB
With negative actuation type electromagnetic brake
*Custom orders are not CE, UL/cUL, RoHS certified. Consult with CKD for details.
Discrete actuator body model no.
Discrete driver model no.
Discrete cable model no.
AX4 T
S
P1
B
AX9000TS U0
AX9000TS J1 U0
AX CBLR6 DM04
Three phase 200 to 20 VAC
Single phase 100 to 115 VAC
A
Size
C
Mounting base
H
Body surface
treatment
G
Dowel
hole
Set model no.
(actuator, driver cable)
E
Brake
Motor cable
Resolver cable
AX CBLM6 DM04
AX4 022
P1
DM04
U0
J1
EB
BS
TS
S
Model
Model no. of options
D
Cable length
DM02 2m
DM04 4m (standard length)
DM06 6m
DM08 8m
DM10 10m
DM15 15m
DM20 20m
I
Interface specifications
I
Interface specifications
I
Interface specifications
U0
Parallel I/O (NPN specifications)
U1
Parallel I/O (PNP specifications)(Coming soon)
U2
CC-Link
U
PROFIBUS-DP
U4
DeviceNet