6- 17
6-2 Detailed Settings (ADVANC)
6-2-1 Hold Settings
Measurement mode
(MEAS)
Function
Refer to
Sample hold
(S-H)
When (and only when) the external input is ON, the
controller holds and outputs the judgment value
(JUDGE.V).
When the external input is OFF, the judgment value
(JUDGE.V) is updated and output (real-time
output).
6-2-1-1
Sample Hold Settings
Peak hold (P-H)
Holds and outputs the maximum value as the
judgment value (JUDGE.V).
6-2-1-2
Peak Hold Settings
Bottom hold (B-H)
Holds and outputs the minimum value as the
judgment value (JUDGE.V).
Peak-to-peak hold (P-P)
Holds and outputs the difference between the
maximum and minimum values as the judgment
value (JUDGE.V).
Peak-to-peak hold/2
(P-P/2)
Holds and outputs half the difference between the
maximum and minimum values as the judgment
value (JUDGE.V).
NG hold (NG-H)
Holds and outputs the LOW and HIGH judgments.
6-2-1-3
NG Hold Settings
Self sample hold
(SLF.S-H)
Static width
After measurement
fluctuations have settled,
automatically self-triggers
holding and output of the
judgment value (JUDGE.V).
6-2-1-4
Self Sample Hold (Static
Width)
Delay timer
After a delay, automatically
self-triggers holding and
output of the judgment value
(JUDGE.V).
6-2-1-5
Self Sample Hold (Delay
Timer)
Self peak hold (SLF.P-H)
Automatically self-triggers holding and output of the
maximum value as the judgment value (JUDGE.V).
6-2-1-6
Self Peak Hold/
Self Bottom Hold
Self bottom hold
(SLF.B-H)
Automatically self-triggers holding and output of the
minimum value as the judgment value (JUDGE.V).
Note
If the calculation app selection function is set to STAND (Difference from standard), the hold
setting of the master unit will be invalid.
Setting the calculation app selection function will invalidate the hold setting of the slave unit used
for the calculation.
■