fn=11: Function 11 Setting Communication Conditions
GS ( E pL pH fn a d1...dk
[Code]
<1D>H<28>H<45>H<pL><pH><fn><a><d1>...<dk>
[Range]
3
≤(pL+pH×256)≤65535(0≤pL≤255, 0≤pH≤255)
fn=11
1
≤a≤4 (Not changed in other than specified range)
48
≤d≤57 (Not changed in other than specified range)
1
≤k≤6
[Outline]
[The specification which is common to the model]
• Sets the communication conditions of serial interface specified by “a”.
• a=1: Setting baud rate
Baud Rate
d1
d2
d3
d4
d5
d6
◎
1200
49(“1”)
50(“2”)
48(“0”)
48(“0”)
-
-
2400
50(“2”)
52(“4”)
48(“0”)
48(“0”)
-
-
4800
52(“4”)
56(“8”)
48(“0”)
48(“0”)
-
-
▲9600
57(“9”)
54(“6”)
48(“0”)
48(“0”)
-
-
△
19200
49(“1”)
57(“9”)
50(“2”)
48(“0”)
48(“0”)
-
38400
51(“3”)
56(“8”)
52(“4”)
48(“0”)
48(“0”)
-
●57600
53(“5”)
55(“7”)
54(“6”)
48(“0”)
48(“0”)
-
●115200
49(“1”)
49(“1”)
53(“5”)
50(“2”)
48(“0”)
48(“0”)
◎
---support by
CT-S280
/
CT-S281
/
CT-S2000
/
CT-S4000
/
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-S310II
/
CT-S251
/
CT-D150
/
CT-E351
●---support by
CT-S280
/
CT-S2000
/
CT-S4000
/
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-S310II
/
CT-S251
/
CT-D150
/
CT-E351
/
CT-D151
/
CT-E651
*
CT-P29x series
does not support 115200bps
.
△
---Default :
CT-S300
/
CT-S310
/
CT-S2000(JPN/EUR)
/
CT-S4000(JPN/EUR)
▲---Default :
CT-S280
/
CT-S281
/
CT-S2000(USA)
/
CT-S4000(USA)
/
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-P29x series
/
CT-S310II
/
CT-S251
/
CT-D150
/
CT-E351
/
CT-D151
/
CT-E651
• a=2: Setting to specified parity
d1
Parity Setting
48 (Default)
No parity
49
Odd parity
50
Even parity
• a=3: Setting to specified flow control
d1
Flow Control
48 (Default)
DSR/DTR
49
XON/XOFF
• a=4: Setting to specified data length
d1
Setting Data Length
55
7-bit length
56 (Default)
8-bit length
• Operates only in printer function setting mode.
• Which of dip SW or memory SW is used at initialization depends on “Selecting communication condition