Chapter 47 Configuring Fabric Configuration Servers
FCS Name Specification
information is not known to both of them. FCS operations can be done only on those switches that are
visible in the VSAN. M2 can send FCS requests only for VSAN 2 even though S3 is also a part of
VSAN 1.
Figure 47-1
FCSs in a VSAN Environment
FCS Characteristics
FCSs have the following characteristics:
•
Support network management including the following:
–
N port management application can query and obtain information about fabric elements.
–
SNMP manager can use the FCS management information base (MIB) to start discovery and
obtain information about the fabric topology.
•
Support TE ports in addition to the standard F and E ports.
•
Can maintain a group of nodes with a logical name and management address when a platform
registers with it. FCSs maintain a backup of all registrations in secondary storage and update it with
every change. When a restart or switchover happens, FCSs retrieve the secondary storage
information and rebuild its database.
•
SNMP manager can query FCSs for all IEs, ports, and platforms in the fabric.
FCS Name Specification
You can specify if the unique name verification is for the entire fabric (globally) or only for locally
(default) registered platforms.
Management
Application 1
Switch 1
(dFCS1)
Management
Application 2
Switch 4
(dFCS4)
Switch 3
(dFCS3)
Switch 2
(dFCS2)
ISL1
ISL2
ISL3
F port
(port VSAN=1)
(port VSAN=2)
F port
VSAN 3
VSAN 2
VSAN 1
85581
N port
Содержание N5010P-N2K-BE
Страница 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 101: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 2 LAN Switching ...
Страница 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 239: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 3 Switch Security Features ...
Страница 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 311: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 4 System Management ...
Страница 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 399: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 5 Fibre Channel over Ethernet ...
Страница 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 417: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 6 Quality of Service ...
Страница 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 435: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 7 SAN Switching ...
Страница 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 657: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 8 Troubleshooting ...
Страница 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...