S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
38-7
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 38 Configuring and Managing Zones
Configuring Zones
Configuring Zones
To configure a zone and assign a zone name, perform this task:
Tip
Use the
show wwn switch
command to retrieve the sWWN. If you do not provide a sWWN, the software
automatically uses the local sWWN.
The following examples show how to configure zone members:
switch(config)#
zone name MyZone vsan 2
pWWN example:
switch(config-zone)#
member pwwn 10:00:00:23:45:67:89:ab
Command
Purpose
Step 1
switch#
configuration terminal
Enters configuration mode.
Step 2
switch(config)#
zone name
zone-name
vsan
vsan-id
Configures a zone in the specified VSAN.
Note
All alphanumeric characters or one of the
following symbols ($, -, ^, _) are supported.
Step 3
switch(config-zone)#
member
type value
Configures a member for the specified zone based on
the type (pWWN, fabric pWWN, FC ID, fcalias,
domain ID, or interface) and value specified. See
Table 38-1
for details.
Caution
You must only configure pWWN-type
zoning on all SAN switches running Cisco
NX-OS if there is a Cisco MDS 9020
switch running FabricWare in the same
fabric.
Tip
Use a relevant display command (for example,
show interface
or
show flogi database
) to
obtain the required value in hex format.
Table 38-1
Type and Value Syntax for the member Command
Domain ID
member domain-id
domain-id
portnumber
number
FC alias
member fcalias
fc-alias-name
FC ID
member fcid
fcid
Fabric pWWN
member fwwn
fwwn-id
Local sWWN interface
member interface
type
slot
/
port
Domain ID interface
member interface
type
slot/port
domain-id
domain-id
Remote sWWN interface
member interface
type
slot
/
port
swwn
swwn-id
pWWN
member pwwn
pwwn-id
Содержание N5010P-N2K-BE
Страница 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 101: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 2 LAN Switching ...
Страница 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 239: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 3 Switch Security Features ...
Страница 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 311: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 4 System Management ...
Страница 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 399: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 5 Fibre Channel over Ethernet ...
Страница 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 417: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 6 Quality of Service ...
Страница 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 435: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 7 SAN Switching ...
Страница 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 657: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 8 Troubleshooting ...
Страница 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...