S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
33-3
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 33 Configuring Domain Parameters
Information About Fibre Channel Domains
•
Enabling Autoreconfiguration, page 33-6
About Domain Restart
Fibre Channel domains can be started disruptively or nondisruptively. If you perform a disruptive restart,
reconfigure fabric (RCF) frames are sent to other switches in the fabric and data traffic is disrupted on
all the switches in the VSAN (including remotely segmented ISLs). If you perform a nondisruptive
restart, build fabric (BF) frames are sent to other switches in the fabric and data traffic is disrupted only
on the switch.
If you are attempting to resolve a domain ID conflict, you must manually assign domain IDs. A
disruptive restart is required to apply most configuration changes, including manually assigned domain
IDs. Nondisruptive domain restarts are acceptable only when changing a preferred domain ID into a
static one (and the actual domain ID remains the same).
Note
A static domain is specifically configured by the user and may be different from the runtime domain. If
the domain IDs are different, the runtime domain ID changes to take on the static domain ID after the
next restart, either disruptive or nondisruptive.
Tip
If a VSAN is in interop mode, you cannot disruptively restart the fcdomain for that VSAN.
You can apply most of the configurations to their corresponding runtime values. Each of the following
sections provide further details on how the fcdomain parameters are applied to the runtime values.
The
fcdomain restart
command applies your changes to the runtime settings. Use the
disruptive
option
to apply most of the configurations to their corresponding runtime values, including preferred domain
IDs (see the
“About Domain IDs” section on page 33-7
).
Restarting a Domain
To restart the fabric disruptively or nondisruptively, perform this task:
About Domain Manager Fast Restart
When a principal link fails, the domain manager must select a new principal link. By default, the domain
manager starts a build fabric (BF) phase, followed by a principal switch selection phase. Both of these
phases involve all the switches in the VSAN, and together take at least 15 seconds to complete. To reduce
the time required for the domain manager to select a new principal link, you can enable the domain
manager fast restart feature.
Command
Purpose
Step 1
switch#
configuration terminal
switch(config)#
Enters configuration mode.
Step 2
switch(config)#
fcdomain restart vsan
vsan-id
Forces the VSAN to reconfigure without traffic
disruption.
switch(config)#
fcdomain restart disruptive
vsan
vsan-id
Forces the VSAN to reconfigure with data
traffic disruption.
Содержание N5010P-N2K-BE
Страница 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 101: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 2 LAN Switching ...
Страница 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 239: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 3 Switch Security Features ...
Страница 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 311: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 4 System Management ...
Страница 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 399: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 5 Fibre Channel over Ethernet ...
Страница 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 417: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 6 Quality of Service ...
Страница 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 435: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 7 SAN Switching ...
Страница 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 657: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 8 Troubleshooting ...
Страница 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...