S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
21-5
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 21 Using Cisco Fabric Services
CFS Distribution
Figure 21-2
Network Example 2 with Fibre Channel and IP Connections
Figure 21-3
is the same as
Figure 21-2
except that node D and node E are connected using IP. Both node
C and node D forward the event to E because the node E is not in the distribution list from node B.
Figure 21-3
Network Example 3 with Fibre Channel and IP Connections
CFS Distribution over Fibre Channel
For FCS distribution over Fibre Channel, the CFS protocol layer resides on top of the FC2 layer. CFS
uses the FC2 transport services to send information to other switches. CFS uses a proprietary SW_ILS
(0x77434653) protocol for all CFS packets. CFS packets are sent to or from the switch domain controller
addresses.
CFS Distribution Scopes
Different applications on the Cisco Nexus 5000 Series switches need to distribute the configuration at
various levels. The following levels are available when using CFS distribution over Fibre Channel:
•
VSAN level (logical scope)
Applications that operate within the scope of a VSAN have the configuration distribution restricted
to the VSAN. An example application is port security where the configuration database is applicable
only within a VSAN.
Note
Logical scope is not supported for FCS distribution over IP.
•
Physical topology level (physical scope)
Some applications (such as NTP) need to distribute the configuration to the entire physical topology.
•
Between two selected switches
Some applications operate only between selected switches in the network.
Node A
Node B
Node C
Node E
Node D
FC
IP
144861
Node A
Node B
Node C
Node E
Node D
FC
IP
144862
Содержание N5010P-N2K-BE
Страница 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 101: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 2 LAN Switching ...
Страница 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 239: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 3 Switch Security Features ...
Страница 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 311: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 4 System Management ...
Страница 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 399: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 5 Fibre Channel over Ethernet ...
Страница 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 417: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 6 Quality of Service ...
Страница 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 435: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 7 SAN Switching ...
Страница 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Страница 657: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m P A R T 8 Troubleshooting ...
Страница 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...