Change the Carrier Mode of a Selected Carrier
4004834 Rev D
89
Change the Carrier Mode of a Selected Carrier
This function allows you to toggle RF output to either a modulated (normal) carrier
mode or a continuous wave (CW) carrier mode.
Important!
The carrier mode established from the front panel of the GoQAM is not
recorded by the DNCS. At the next GoQAM restart, the carrier mode for the
GoQAM reverts to the value stored in the DNCS.
Selecting Modulated or Continuous Wave Carrier Mode
Follow these steps to change the carrier mode for an RF module.
1
Press
CW
. The Carrier Mode screen appears.
2
Press
RF SEL
to choose a channel (CH1 or CH2).
3
Press the Up and Down Arrow keys to toggle the carrier mode between
Modulated (normal) and CW (not modulated or continuous wave).
Note:
The factory default for the carrier mode setting is Modulated.
4
Press
ENTER
. The system saves the carrier mode setting changes to NVRAM
and the default screen appears.
CH1 285.00 MHz 50.0 dBmV
ITUB 64QAM CW Alarm 0
Note:
When choosing CW mode, the CW LED on the front panel of the GoQAM
lights and CW appears on the default screen.