Chapter 8 Troubleshooting the GoQAM
142
4004834 Rev D
“Session
xxx
program
error”
where xxx is a
number from
0 to 991
Minor Cause Code 1 - A cyclic redundancy
check (CRC) error was detected on a
program map table (PMT).
Cause Code 2 - A new PMT was detected.
Cause Code 3 - An attempt to create a
session failed.
Program Specific Information (PSI) table
data changed in the input stream with the
following cause codes:
Cause Code 4 - Program Association
Table (PAT) update
Cause Code 5 - PMT packet identifier
(PID) conflict
Cause Code 6 - Elementary PID
conflict
Cause Code 7 - Entitlement Control
Message (ECM) PID conflict
Cause Code 8 - Program number
conflict
Delete the session.
This is for information
only. No action is
required.
Teardown and rebuild the
session.
Check the upstream
MPEG input sources
connected to the
GoQAM
For Cause Code 8,
teardown and rebuild
the session with a
program number that
does not conflict with
the session
If the alarm does not
automatically clear,
contact Cisco Services
System
Hardware
Alarm
Major The GoQAM cannot communicate with
the RF network.
Check for loose
connections or
defective cables,
tighten any loose cable
connections, and
replace any defective
cables
Reset the GoQAM by
the power switch or, if
possible, by DNCS
control
Contact Cisco Services
Содержание GoQAM
Страница 1: ...GoQAM Modulator RF Output and IF Output Hardware Installation and Operation Guide ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 30: ......
Страница 52: ......
Страница 67: ...Provision GoQAMs on the DNCS 4004834 Rev D 51 ...
Страница 68: ......
Страница 116: ......
Страница 138: ......
Страница 164: ......
Страница 176: ......