Chapter 5 Operating the RF Modulator
82
4004834 Rev D
Changing the Boot Mode
1
Connect a diagnostic PC to the
CRAFT PORT
on the back panel of the GoQAM.
2
Power on the diagnostic PC and activate a Procomm or Hyperterminal window
using the following modem connection settings:
9600 baud
1 stop bit
No parity
8 data bits
No flow control
3
Power on the GoQAM; then, during the boot sequence, watch for the following
message on the PC monitor screen:
Type any key within 2 seconds to get shell prompt
Note:
See the
Connect Power Sources
(on page 27) section for more details about
powering on the GoQAM.
4
Press any key on the PC to display the boot prompt. The following boot prompt
appears:
boot>
Note:
If you do not press a key in time to get the boot prompt, do one of the
following:
Cycle power to the GoQAM, and repeat this step. See Resetting the
Modulator for more details.
At the
GoQAM>
prompt, type
boot
; then, after the
Type any key
message
appears, press any key to display the boot prompt.
5
At the boot prompt, type
setbootmode
and press
Enter
. The current boot mode
setting appears.
6
Type one of the following numbers to select the boot mode:
0
- Skip BootP
1
- Attempt BootP One Time
2
- Bootp Until Successful
Result:
The system saves the new boot mode to nonvolatile memory (NVRAM)
with the new setting.
7
Type
exit
and press
Enter
. The GoQAM reboots using the new boot mode.
8
Disconnect the diagnostic PC.
Содержание GoQAM
Страница 1: ...GoQAM Modulator RF Output and IF Output Hardware Installation and Operation Guide ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 30: ......
Страница 52: ......
Страница 67: ...Provision GoQAMs on the DNCS 4004834 Rev D 51 ...
Страница 68: ......
Страница 116: ......
Страница 138: ......
Страница 164: ......
Страница 176: ......