33-20
Catalyst 2928 Switch Software Configuration Guide
OL-23389-01
Chapter 33 Troubleshooting
Using the show platform forward Command
The
no debug all
privileged EXEC command disables all diagnostic output. Using the
no debug all
command is a convenient way to ensure that you have not accidentally left any
debug
commands
enabled.
Redirecting Debug and Error Message Output
By default, the network server sends the output from
debug
commands and system error messages to the
console. If you use this default, you can use a virtual terminal connection to monitor debug output
instead of connecting to the console port.
Possible destinations include the console, virtual terminals, internal buffer, and UNIX hosts running a
syslog server. The syslog format is compatible with 4.3 Berkeley Standard Distribution (BSD) UNIX
and its derivatives.
Note
Be aware that the debugging destination you use affects system overhead. Logging messages to the
console produces very high overhead, whereas logging messages to a virtual terminal produces less
overhead. Logging messages to a syslog server produces even less, and logging to an internal buffer
produces the least overhead of any method.
For more information about system message logging, see
Chapter 28, “Configuring System Message
Using the show platform forward Command
The output from the
show platform forward
privileged EXEC command provides some useful
information about the forwarding results if a packet entering an interface is sent through the system.
Depending upon the parameters entered about the packet, the output provides lookup table results and
port maps used to calculate forwarding destinations, bitmaps, and egress information.
Note
For more syntax and usage information for the
show platform forward
command, see the switch
command reference for this release.
Most of the information in the output from the command is useful mainly for technical support
personnel, who have access to detailed information about the switch application-specific integrated
circuits (ASICs). However, packet forwarding information can also be helpful in troubleshooting.
This is an example of the output from the
show platform forward
command on port 1 in VLAN 5 when
the packet entering that port is addressed to unknown MAC addresses. The packet should be flooded to
all other ports in VLAN 5.
Switch#
show platform forward gigabitethernet0/1 vlan 5 1.1.1 2.2.2 ip 13.1.1.1 13.2.2.2
udp 10 20
Global Port Number:24, Asic Number:5
Src Real Vlan Id:5, Mapped Vlan Id:5
Ingress:
Lookup Key-Used Index-Hit A-Data
InptACL 40_0D020202_0D010101-00_40000014_000A0000 01FFA 03000000
L2Local 80_00050002_00020002-00_00000000_00000000 00C71 0000002B
Station Descriptor:02340000, DestIndex:0239, RewriteIndex:F005
==========================================
Содержание Catalyst 2928
Страница 28: ...Contents xxviii Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...
Страница 32: ...xxx Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Preface ...
Страница 496: ...26 14 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 26 Configuring SPAN Displaying SPAN Status ...
Страница 534: ...29 18 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 29 Configuring SNMP Displaying SNMP Status ...
Страница 700: ...Index IN 36 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...