12-16
Catalyst 2928 Switch Software Configuration Guide
OL-23389-01
Chapter 12 Configuring Interface Characteristics
Configuring Ethernet Interfaces
To return to the default setting, use the
no media-type
interface configuration command.
When you change the interface type, the speed and duplex configurations are removed. The switch
configures both types to autonegotiate speed and duplex (the default). If you configure
auto-select
, you
cannot configure the
speed
and
duplex
interface configuration commands.
When the switch powers on or when you enable a dual-purpose uplink port through the
shutdown
and
the
no shutdown
interface configuration commands, the switch gives preference to the SFP module
interface. In all other situations, the switch selects the active link based on which type first links up.
The Catalyst 2928 switch operates with 100BASE-
x
(where -
x
is -BX, -FX-FE, -LX) SFP modules as
follows:
•
When the 100BASE -
x
SFP module is inserted into the module slot and there is no link on the RJ-45
side, the switch disables the RJ-45 interface and selects the SFP module interface. This is the
behavior even if there is no cable connected and if there is no link on the SFP module side.
•
When the 100BASE-
x
SFP module is inserted and there is a link on the RJ-45 side, the switch
continues with that link. If the link goes down, the switch disables the RJ-45 side and selects the
SFP module interface.
•
When the 100BASE-
x
SFP module is removed, the switch again dynamically selects the type
(
auto-select
) and re-enables the RJ-45 side.
The switch does not have this behavior with 100BASE-FX-GE SFP modules.
Step 3
media-type
{
auto-select
|
rj45
|
sfp
}
Select the interface and type of a dual-purpose uplink port. The keywords
have these meanings:
•
auto-select
—The switch dynamically selects the type. When link up is
achieved, the switch disables the other type until the active link goes
down. When the active link goes down, the switch enables both types
until one of them links up. In auto-select mode, the switch configures
both types with autonegotiation of speed and duplex (the default).
Depending on the type of installed SFP module, the switch might not
be able to dynamically select it. For more information, see the
information that follows this procedure.
•
rj45
—The switch disables the SFP module interface. If you connect a
cable to this port, it cannot attain a link even if the RJ-45 side is down
or is not connected. In this mode, the dual-purpose port behaves like a
10/100/1000BASE-TX interface. You can configure the speed and
duplex settings consistent with this interface type.
•
sfp
—The switch disables the RJ-45 interface. If you connect a cable to
this port, it cannot attain a link even if the SFP module side is down or
if the SFP module is not present. Based on the type of installed SFP
module, you can configure the speed and duplex settings consistent
with this interface type.
For information about setting the speed and duplex, see the
Duplex Configuration Guidelines” section on page 12-17
.
Step 4
end
Return to privileged EXEC mode.
Step 5
show interfaces
interface-id
transceiver properties
Verify your setting.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Содержание Catalyst 2928
Страница 28: ...Contents xxviii Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...
Страница 32: ...xxx Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Preface ...
Страница 496: ...26 14 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 26 Configuring SPAN Displaying SPAN Status ...
Страница 534: ...29 18 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 29 Configuring SNMP Displaying SNMP Status ...
Страница 700: ...Index IN 36 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...