Gx Interface Support
▀ Rel. 8 Gx Interface
▄ Cisco ASR 5x00 Packet Data Network Gateway Administration Guide
308
information of the predefined PCC rules and takes this information into account when activating them. This ensures that
the combined authorized QoS of a set of PCC rules that are activated by the PCRF is within the limitations given by the
subscription and operator policies regardless of whether these PCC rules are dynamically provided, predefined, or both.
Supported features include:
Provisioning and Policy Enforcement of Authorized QoS: The PCRF may provide authorized QoS to the PCEF.
The authorized QoS provides appropriate values for resources to be enforced.
Policy Provisioning for Authorized QoS Per SDF: The provisioning of authorized QoS per SDF is a part of PCC
rule provisioning procedure.
Policy Enforcement for Authorized QoS Per SDF: If an authorized QoS is defined for a PCC rule, the PCEF
limits the data rate of the SDF corresponding to that PCC rule not to exceed the maximum authorized
bandwidth for the PCC rule by discarding packets exceeding the limit.
Upon deactivation or removal of a PCC rule, the PCEF frees the resources reserved for that PCC rule.
Other Features
This section describes some of the other features.
PCC Rule Error Handling
If the installation/activation of one or more PCC rules fails, the PCEF communicates the failure to the PCRF by
including one or more Charging-Rule-Report AVP(s) in either a CCR or an RAA command for the affected PCC rules.
Within each Charging-Rule-Report AVP, the PCEF identifies the failed PCC rule(s) by including the Charging-Rule-
Name AVP(s) or Charging-Rule-Base-Name AVP(s), identifies the failed reason code by including a Rule-Failure-Code
AVP, and includes the PCC-Rule-Status AVP.
If the installation/activation of one or more new PCC rules (that is, rules that were not previously successfully installed)
fail, the PCEF sets the PCC-Rule-Status to INACTIVE for both the PUSH and the PULL modes.
If a PCC rule was successfully installed/activated, but can no longer be enforced by the PCEF, the PCEF sends the
PCRF a new CCR command and includes the Charging-Rule-Report AVP. The PCEF includes the Rule-Failure-Code
AVP within the Charging-Rule-Report AVP and sets the PCC-Rule-Status to INACTIVE.
In the HA/PDSN Gx implementation, the following rule failure codes are supported:
RATING_GROUP_ERROR (2)
SERVICE_IDENTIFIER_ERROR (3)
GW/PCEF_MALFUNCTION (4)
RESOURCES_LIMITATION (5)
If the installation/activation of one or more PCC rules fails during RAR procedure, the RAA command is sent with the
Experimental-Result-Code AVP set to DIAMETER_PCC_RULE_EVENT (5142).
Time of the Day Procedures
PCEF performs PCC rule request as instructed by the PCRF. Revalidation-Time when set by the PCRF, causes the
PCEF to trigger a PCRF interaction to request PCC rules from the PCRF for an established IP-CAN session. The PCEF
stops the timer once the PCEF triggers a REVALIDATION_TIMEOUT event.
When installed, the PCC rule is inactive. If Rule-Activation-Time / Rule-Deactivation-Time is specified, then the PCEF
sets the rule active / inactive after that time.
Charging Control