66
Raption 50 Series Installation Manual
S O C K E T L E V E L
Raption 50 Series Service Manual
Error
Hexadecimal
Decimal
Description
OK
0x0
0
No error.
CFG
0x1
1
Invalid Configuration.
MASTER
0x2
2
Plug error. Socket is inoperative. Check
plug error affected.
USER_INTERFACE
0X4
4
User Interface error.
LOCK
0x8
8
Lock error.
SUPPLY
0x10
16
Power supply dropped.
RCD
0X20
32
RCD tripped
CONTACTOR
0X40
64
Contactor failed.
METER
0x80
128
Meter failed.
EMERGENCY
0x100
256
Emergency button pressed.
TEMPERATURE
0x200
512
Temperature out of range.
EV_
COMMUNICATION_
DEVICE
0X400
1024
Communication between charge point and
vehicle failed.
EV_CORD
0x800
2048
Proximity pin error. (Mode 3)
OTHER
0x1000
4096
Other error not defined above.
COMMUNICATION
0x2000
8192
One or more devices configured on the
socket are not communicating.
OVERCURRENT
0x4000
16384
Current consumption exceeded.
MCB
0x8000
32768
MCB tripped
VOLTAGE
0x10000
65536
Voltage out of range.
Содержание Raption 50 Gen2 Series
Страница 1: ...Service Manual Raption 50 Gen2 Series ...
Страница 2: ......
Страница 4: ...0 ...
Страница 7: ...03 8 Maintenance 80 9 Annexes 84 10 Technical data 86 11 Need help 90 ...
Страница 12: ...08 Raption 50 Series Service Manual B Dimensions Units specified in millimeters ...
Страница 14: ...10 Raption 50 Series Service Manual 1 ELECTRONIC BOARDS ETC UPPER PART ...
Страница 16: ...12 Raption 50 Series Service Manual 2 POWER MODULES MEDIUM PART 1 7 2 3 4 6 5 13 8 9 12 11 10 ...
Страница 21: ...17 6 BLOCK DIAGRAM ...
Страница 23: ...19 Raption 50 Series Service Manual ...
Страница 55: ...51 ...
Страница 94: ...90 Raption 50 Series Instruction Manual 11 Raption 50 Series Service Manual ...