50
Raption 50 Series Installation Manual
Raption 50 Series Service Manual
DC Output Contactors:
There are 5 DC output contactors:
•
Two for CHAdeMO cable.
•
Two for CCS2 cable.
•
One for CCS2 precharge circuit.
Raption 50 Gen 2 mounts different output contactors than Raption Gen 1. These
ones allow Welding detection function. When one of the contactors is welded,
Mode 4 control board will receive this information and will identify which is
the faulty contactor. An alarm will be generated to avoid incoming charging
sessions.