64
Raption 50 Series Installation Manual
C H A R G E P O I N T L E V E L
Raption 50 Series Service Manual
Error
Hexadecimal
Decimal
Description
OK
0x0
0
No error
CFG
0x1
1
Invalid Configuration
READER
0x2
2
Reader Error.
DISPLAY
0X4
4
Display Error.
TAMPER
0x8
8
Tamper Error.
TILT
0x10
16
Charge point is tilted.
SUPPLY
0X20
32
Power Supply dropped.
RCD
0X40
64
RCD dropped.
TEMPERATURE
0x80
128
Temperature out of range
OTHER
0x100
256
Other error not defined above.
COMMUNICATION
0x200
512
One or more devices configured on the charge
point are not communicating.
TYPE
0X400
1024
Device installed is not the same as configured.
VERSION
0x800
2048
Incorrect device version.
GROUND
0x1000
4096
PE error.
MCB
0x2000
8192
Charge Point MCB tripped
OFFLINE
0x4000
16384
Charge point is offline
Содержание Raption 50 Gen2 Series
Страница 1: ...Service Manual Raption 50 Gen2 Series ...
Страница 2: ......
Страница 4: ...0 ...
Страница 7: ...03 8 Maintenance 80 9 Annexes 84 10 Technical data 86 11 Need help 90 ...
Страница 12: ...08 Raption 50 Series Service Manual B Dimensions Units specified in millimeters ...
Страница 14: ...10 Raption 50 Series Service Manual 1 ELECTRONIC BOARDS ETC UPPER PART ...
Страница 16: ...12 Raption 50 Series Service Manual 2 POWER MODULES MEDIUM PART 1 7 2 3 4 6 5 13 8 9 12 11 10 ...
Страница 21: ...17 6 BLOCK DIAGRAM ...
Страница 23: ...19 Raption 50 Series Service Manual ...
Страница 55: ...51 ...
Страница 94: ...90 Raption 50 Series Instruction Manual 11 Raption 50 Series Service Manual ...