38
Raption 50 Series Installation Manual
Electrical scheme
Settings
While in Raption 50 Gen1 there were two Isolation protection devices, one for
CHAdeMO and another one for CCS, in Raption 50 Gen2 there is only one device
(Bender) monitoring and protecting both connectors.
Each connector (CHA and CCS) has its own protection parameters, so depending
on which one is being used, Bender will need to adjust to the corresponding
values. By default it is configured with CCS settings. However, when a CHAdeMO
charging session is about to start, Mode 4 board sends the values for this
connector.
Bender device can be configured manually using its buttons or via software.on
RS485 communications.
Check the Annexes to find the configuration steps in case service staff has to do
the settings manually.
When device is configured via software, ask
to get
the necessary files.