![background image](http://html.mh-extra.com/html/circontrol/raption-50-gen2-series/raption-50-gen2-series_service-manual_2607963079.webp)
75
Raption 50 Series Service Manual
SSL/TLS error
HTTPS URL’s requires a certificate that must to be uploaded to the OCPP
integrations webpage.
The Certificate uploaded is not correct.
Time and Date are not correctly synchronised
Getting valid public ID timeout
Raption / eVolve Master:
•
The password of the modem (f.e. admin01 in Teltonika Rut240) has been
changed. It cannot be changed.
•
Check the list of Blocked IPs of the modem. If IP of the charger is included
there, remove it from the list
Evolve / WB Smart
•
Check if Network > Public Address Manager is selected as Embedded modem
•
Check with Sim card provider if Sim card is activated (In some cases Roaming
is required too)