OCPP Errors
Most common troubles establishing communications with a Central System.
OCPP 1.5
Connect failed in tcp_connect
Common causes:
Host URL introduced is not correct. Check it on OCPP configuration.
Raption / eVolve Master:
•
Check if DHCP=ON whithin Network section on web page from CP. Reboot
required.
Evolve / WB Smart:
•
Check if embedded modem is connected to the network. Otherwise check
modem parameters (some celullar providers requires especial APN
configuration).
•
If no modem. Then ethernet IP address must be static, using gateway and
DNS from this network. Do not use DHCP=ON
Detail: bind failed in soap_bind /’ ‘Error 28’
OCPP Listening Ports configured already used by default by the unit: 80, 8080,
65432, 22.
Can not get charge device name
The internal application of charge point is corrupted/lost or is not installed.
It requires to upload a file provided by post sales support within Configuration
Update section on web page of the charge point.
Содержание Raption 50 Gen2 Series
Страница 1: ...Service Manual Raption 50 Gen2 Series ...
Страница 2: ......
Страница 4: ...0 ...
Страница 7: ...03 8 Maintenance 80 9 Annexes 84 10 Technical data 86 11 Need help 90 ...
Страница 12: ...08 Raption 50 Series Service Manual B Dimensions Units specified in millimeters ...
Страница 14: ...10 Raption 50 Series Service Manual 1 ELECTRONIC BOARDS ETC UPPER PART ...
Страница 16: ...12 Raption 50 Series Service Manual 2 POWER MODULES MEDIUM PART 1 7 2 3 4 6 5 13 8 9 12 11 10 ...
Страница 21: ...17 6 BLOCK DIAGRAM ...
Страница 23: ...19 Raption 50 Series Service Manual ...
Страница 55: ...51 ...
Страница 94: ...90 Raption 50 Series Instruction Manual 11 Raption 50 Series Service Manual ...