EES3 Hardware Interface Description
5.3 Storage Conditions
99
EES3_HD_v01.100b
Page 78 of 118
2009-08-12
Confidential / Released
5.3
Storage Conditions
The conditions stated below are only valid for modules in their original packed state in weather
protected, non-temperature-controlled storage locations. Normal storage time under these
conditions is 12 months maximum.
Table 24:
Storage conditions
Type
Condition
Unit
Reference
Air temperature: Low
High
-25
+40
°C
IPC/JEDEC J-STD-033A
Humidity relative: Low
High
10
90 at 40°C
%
IPC/JEDEC J-STD-033A
Air pressure: Low
High
70
106
kPa
IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air
1.0
m/s
IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed
---
---
Radiation:
Solar
Heat
1120
600
W/m
2
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Chemically active substances
Not
recommended
IEC TR 60271-3-1: 1C1L
Mechanically active substances
Not
recommended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
1.5
5
2-9 9-200
mm
m/s
2
Hz
IEC TR 60271-3-1: 1M2
Shocks:
Shock spectrum
Duration
Acceleration
semi-sinusoidal
1
50
ms
m/s
2
IEC 68-2-27 Ea