![Cimbali FAEMA Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/cimbali/faema/faema_use-and-installation_2607156082.webp)
A
B
Cs
Ts
6b
1
2
3
4
6
Fs
Hs
Hs
5
8
6b
P
P
7
English
30 EN
SOLUBLES HOPPER CLEANING (6b), where present
The solubles hopper (
6b
) must be periodically cleaned (every
week, approximately). Depending on consumption and type
of product, cleaning can be performed more frequently.
The images opposite are that of a double solubles hopper.
Please follow these steps:
1) Open the lock (
A
);
2) Open the control panel (
B
);
3) Push the hopper closing device (
Hs
) towards the back
of the machine;
4) Open the hopper lock (
Ts
) and remove the cover (
Cs
);
5) Use a tool to turn the fastening device (
Fs
) counter-
clockwise;
6) Move the hopper towards the front of the machine;
7) Slightly raise the rear of the hopper and remove the
solubles hopper (
6b
) from the machine;
8) Remove the 2
wheel stop
(
P
);
open
closed
12. Cleaning operations
Level 2