Link 50 - 55
1-2009
68
L
ink
S
50
L
ink
S
50
basso
volum
e
basso
volume
®
+
-
ON
ON
OFF
OFF
Spin
Remote
Control
H O
2
Press.
Pump
15.6 - TANK REMOVAL OR REPLACEMENT
This operation has to be carried out by a C.I.M.A. service point
The operation has to be carried out by complete absence of liquid residuals both
inside the tank and in the hydraulic circuit.
1.
Make the tank free from all the hydraulic and pneumatic connections.
2.
Loosen the screw nut (4), for tensioning the tank fastening belt.
3.
Remove the split pin (3).
4.
Unscrew the belt end (2), in order to make the tank free; carry out the same operation for the second
belt (1).
5.
Lift the tank and remove it from the frame.
Before reassembling the main tank check the integrity of the rubber supports
glued on the frame; if damaged or particularly worn replace them.
6.
Position the tank on the frame.
7.
Reposition the anchorage belts in their own seats.
8.
Screw the regulation nut on each belt so that they are tight enough to firmly secure the tank to the
frame.
9.
Replace both the safety pins.
The adjustment of the belts takes place during the first 3÷4 hours of use of the
atomizer; after this period check and restore the correct tension of the belts so
that the perfect block of the main tank to the frame will be guaranteed, this way
preventing any damages or breakups of the tank itself.
Before every treatment, check the tension of the tank anchorage belts.
LEGENDA
1 - FRONT BELT
2 - REAR BELT
3 - SPLIT PIN
4 - SCREW NUT
00332
2
1
2
3
4
Содержание Link
Страница 4: ......
Страница 85: ...1 2009 Link 50 55 NOTES ...