Link 50 - 55
1-2009
58
Carefully tighten all the fastening collars’ bolts.
13.6 - FAN BELT TENSIONER
Check length “L” of the spring (refer to Picture): it should be in tension between
9
and
12
cm.
00321
00230
L = 9 ÷ 12 cm
L
ink
S
50
L
ink
S
50
basso
volume
basso
volume
®
+
-
ON
ON
OFF
OFF
Spin
Remote
Control
H O
2
Press.
Pump
If the fan control belt has to be replaced, the correct tensioning of the same one
(spring length) has to be OBLIGATORILY checked after the first and after the
second operation hour.
If the value measured exceeds 12 cm, tighten the belt tightener screw, up to get
the minimum length (9 cm).
The belt setting will take place within the first 2÷3 operating hours; when that time has elapsed, verify
the spring length, according with the time intervals (periodicity) indicated in the “Maintenance
operations’ table”.
13.7 - PUMP BELT TENSIONER
Check length “L” of the spring (refer to picture): it should be in tension between
4 and 5
cm.
00231
L = 4 ÷ 5 cm
L
ink
S
50
L
ink
S
50
basso
volume
basso
volume
100
200
300
400
500
600
700
800
LT
00320
If the value measured exceeds 5 cm, tighten the belt tightener screw, up to get the minimum length
(4 cm).