Section 2: Adjust the Image
Solaria One/Solaria One
+
Service Manual
2-5
020-101039-02 Rev. 1 (06-2013)
Only adjust horizontal boresight 1/8 of a turn or less at one time to maintain
optimal lens performance (i.e. factory setup of absolute lens distance to the prism). It is
critical that you count each turn of the cap screws to ensure accurate adjustment.
Typically, horizontal boresight does not require adjustment. It should only be adjusted if a large horizontal
angular offset to the screen is required.
1. Remove the lens surround.
2. Display the DC2K Framing test pattern:
a. On the touch panel controller (TPC), tap the
Test Pattern
icon (
)
in the task bar.
b. Tap
All Test Patterns
.
c. Tap
DC2K Framing
.
3. Loosen the right boresight set screw (B).
4. Turn the right boresight cap screw (A) 1/16 of a turn clockwise.
5. Adjust the left boresight cap screw (C) equally in the opposite direction.
6. If the quality of the projected image has not improved, turn the right boresight cap screw 1/16 of turn
counter-clockwise. Make sure the left adjuster is adjusted equally in the opposite direction.
A
Right Boresight Cap Screw
B
Right Boresight Set Screw
C
Left Boresight Cap Screw
D
Left Boresight Set Screw
A
B
C
D